DICOM/HL7 11-3
Name Description
Ping
You can ping the other machines after you entered the correct IP address.
Besides, you can select a server in the Device list to ping it.
Device List Displays the added device.
Set DICOM
Service
Provides server settings of DICOM service, for details, please refer to the
following chapters.
Add Click to add server (s) to the Device List.
Delete Click to delete the selected server (s) in the device list.
Log Level
Select the log display level: No Log, Service Result Log, Service Process
Log, All Log.
Set DICOM
Strategy
Provides strategy settings of DICOM service, for details, please refer to the
following chapters.
Server setting procedure:
1. Enter the server device name and IP address; click [Ping] to check the connection.
2. Click [Add] to add the server to the device list, and its name and address are displayed in the list.
Tips:
AE Title should be the same with the SCU AE Title preset in the server (PACS/RIS/HIS), for
example, if the AE Title of the server preset in the storage server is Storage, and the AE Title of the
accepted SCU is preset as Machine, then in the figure above, the AE Title of Local should be
Machine, and the AE Title of storage server should be Storage.
The device name is random. If the server name is same with that in the DICOM server list, the
information the server added already exits, click [Ok] to retype the name.
4001600030016555 cannot be set as the port.
IP address should be the address of the remote server.
11.1.3 Service Preset
The DICOM Service screen is used to set attributes of Storage, Print, WorkList, MPPS, Storage
Commitment, and Query/Retrieve.
When the system is configured with DICOM basic function module, and installed with DICOM WorkList,
MPPS, DICOM structured report, and DICOM query/retrieve modules, the corresponding preset can be
found in DICOM Service screen.
11.1.3.1 Storage Service Preset
1. On the DICOM Service screen, click the [Storage] page tab to enter the Storage page.
2. Select a device and enter the correct AE Title, port, etc.
3. Click [Add] to add the service to the Service List.