FAULT SIGNALS
TYPE DESCRIPTION SOLUTION
E00 No gas check:
- the gas pipe is connected to the machine,
- the gas tap on the cylinder is open,
- the outlet pressure is between 1.0 and 1.5 bar.
PRESS KEY (O) TO RESET THE ERROR.
E01 cover open during cycle - gas injection time too high,
- cover seal faulty.
PRESS KEY (O) TO RESET THE ERROR
E02 the cover does not open after air return check:
- the gas springs are not released,
- the AIR RETURN EV is not faulty,
- the pneumatic circuit is correctly connected,
- the electrical circuit is correctly connected
PRESS KEY (O) TO RESET THE ERROR.
E03 cover remains closed when machine powered on check:
- the gas springs are not released,
- power is available during the vacuum cycle.
PRESS KEY (O) TO RESET THE ERROR.
.
E08 change oil change the pump oil as instructed in the attached booklet.
PRESS KEY (O) TO RESET THE ALARM and run a new vacuum cycle.
CONTACT CUSTOMER ASSISTANCE TO RESET THE OIL CHANGE.
E09 fatal error switch off the machine promptly and contact technical support.
EF motor phase inverted invert two phases in the plug