WARNING: Risk of Electrical Shock. Hazardous live parts inside
these power supplies are energized from the battery even when the
AC input is disconnected.
CAUTION! To de-energize the outputs of the UPS:
1. If the UPS is on press and release the On/Off/Test Button.
2. Disconnect the UPS from the AC wall outlet.
3. To de-energize the UPS completely, disconnect the battery.
CAUTION! To reduce the risk of electrical shock in conditions
where the load equipment grounding cannot be verified, disconnect
the UPS from the AC wall outlet before installing a computer interface
cable. Reconnect the power cord only after all signaling connections
are made.
CAUTION! Connect the UPS to a two pole, three wire grounding
AC wall outlet. The receptacle must be connected to the appropriate
branch protection (circuit breaker or fuse). Connection to any other
type of receptacle may result in a shock hazard and violate local
electrical codes. Do not use extension cords, adapter plugs, or surge
strips.
English
CAUTION! To reduce the risk of electrical shock with the installa-
tion of this UPS equipment and the connected equipment, the user
must ensure that the combined sum of the AC leakage current does
not exceed 3.5mA.
This symbol indicates "Direct Current Supply"
This symbol indicates "Equipment Grounding Conductor"
WARNING: This Uninterruptible Power Supply contains potentially
hazardous voltages. Do not attempt to disassemble the UPS beyond
the battery replacement procedure. This UPS contains no user ser-
viceable parts. Repairs and Battery replacement must be performed
by QUALIFIED SERVICE PERSONNEL ONLY.
CAUTION! To reduce the risk of fire, connect only to a circuit
provided with 20 amperes maximum branch circuit over-current pro-
tection in accordance with the National Electric Code, ANSI/NFPA
70.
IMPORTANT SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS !
English
Thank you for purchasing this power protection product. It has been designed
and manufactured to provide many years of trouble free service.
Please read this manual before installing your PRO Rack/Tower Series UPS,
models PRO1000RT, PRO1500RT as it provides important information that
should be followed during installation and maintenance of the UPS and batter-
ies allowing you to correctly set up your system for the maximum safety and
performance. Included is information on customer support and factory service
if it is required. If you experience a problem with the UPS please refer to the
Troubleshooting guide in this manual to correct the problem or collect enough
information so that the Technical Support Department can rapidly assist you.