Page #24 background imageLoading...
Page #24 background image
241062243-W2-N
Symptom Start/
Stop
Light
Heater
Setting
I / II / III
Probable Cause Possible Remedy
No change in
temperature
between I/II/III
settings.
ON ANY
Insufficient mains water
pressure.
Contact local water company.
Possible failure of ow valve,
microswitch or heater tank.
Check the continuity of the
microswitch or heater tank and
replace parts as necessary.
Water will not
turno󰀨.
ON ANY
Inlet valve, solenoid, or start/
stop switch faulty.
Replaceasnecessary.
Supply pressure below 0.2 bar. Contact local water company.
Check mains water static
pressure.
Appliance fails
to produce hot
water when set
on II/III heater
settings.
ON II / III
Insu󰀩cientwatersupply Contact local water company.
Possible failure of the
microswitch or thermal switch.
Check the continuity of the
microswitch or heater tank and
replace parts as necessary.
Heater Tank failure. Replace.