20
Symptom Start/
Stop
Light
Heater
Setting
I/II/III
Probable Cause Possible Remedy
L o w o r n o
ow.
ON
ON
ON
ON
OFF
ON
ON
Any
Any
Any
Any
Any
Any
Any
Water supply pipework or inlet
lter restricted by a blockage or
partial blockage.
Insufficient water su p p l y
pressure/ow for operation.
Other outlets (e.g. toilet, garden
hose, washing machine, etc.)
drawing water while the shower
is being used.
Handset blocked.
Service tunnel or cover not
tted correctly causing Start/
Stop button not to operate.
Inlet Valve faulty.
Heate r Tan k exces s i v ely
scaled.
Flush supply pipe. Clean inlet
lter.
Contact local water company.
Supply pressure must be a
minimum of 0.7 bar. Note: If
other appliances are operating,
pressure may drop below 0.7
bar.
Turn off other appliances whilst
shower is in use.
Remove and clean.
Check case inserts are cut and
tted correctly. Check services
(electrical or plumbing) are
not interfering with location of
service tunnel or cover.
Replace.
Replace. In hard water areas
consider the use of a water
softener.
Operation of
te mp e r a tu re
c o n t r o l h a s
l i t t l e o r n o
effect on water
temperature.
ON
ON
ON
ON
II/III
II/III
II/III
II/III
Handset or inlet lter blocked.
Inlet valve faulty.
Heater tank failure.
Microswitch failure.
Remove and clean.
Replace.
Replace.
Replace.
No change in
te mp e r a tu re
between I/II/III
settings.
ON
ON
Any
Any
In s uff i ci e nt m ai n s w a te r
pressure.
Possible failure of ow valve,
microswitch or heater tank.
Contact local water company.
Check the continuity of the
microswitch or heater tank and