SPECIFICATIONS
1. Plumbing
1.1. Minimum maintained inlet pressure:
9.5 kW = 70 kPa (0.7 bar)
10.8 kW = 100 kPa (1 bar)
1.2. Maximum static inlet pressure of 1000 kPa (10 bar).
1.3. Minimum static inlet pressure of 50 kPa (0.5 bar) to keep the inlet valve
closed.
2. Electrical
2.1. The Mira Elevate 9.5 kW requires a 40 Amp circuit protection device.
The Mira Elevate 10.8 kW requires a 45 Amp circuit protection device.
2.2. 
2
.
3. Standards and Approvals
3.1. The Mira Elevate complies with all relevant directives for CE marking.
INSTALLATION REQUIREMENTS
Plumbing
1. When installed in very hard water areas (above 200 ppm temporary hardness)
your installer may advise the installation of a water treatment device, to reduce
the effects of limescale formation. Your local water company will be able to
advise the hardness of water in your area.
 
as part of the cold water supply pipe to allow the complete maintenance of the
appliance. Do not use a valve with a loose washer plate (jumper) as this can
lead to the build up of static pressure.
 
with a pressure relief device and must be positioned over a water catchment
area with the controls at a convenient height for all users.