21
Front Mounted (maximum thickness 13 mm)
To fit the Form shower control to the front face of a panel, a further finishing layer
(e.g. plaster and tiles) must be applied to the panel to cover over the wall mounting
plate and fixing screws. This finishing layer can be between 6 mm and 21 mm thick.
The laminated panel can be a maximum of 13 mm thick.
Follow the instructions in section: ‘Installation: solid and dry lined walls’ to install
the shower control and fittings. Refer to section: ‘Commissioning’ before operating
the shower control.
Laminated Panel
(maximum thickness 13 mm)
Concealing Plate
Foam Seal
Concealing Plate
Outlet Support
Bracket
Wall Clamp Nut
Outlet Seal
Right Angle
Connector
Locknut
and Trim
Control Knob
Assembly
If the shower is front panel
mounted a further finishing
surface (6 mm to 21 mm thick)
must be applied to the panel.