Solid Wall or Stud Partition Fixing
using Securing Brackets
1. Refer to section: ‘Rear Fixing into Solid Walls
or Stud Partitions’ and follow instructions
1 to 4.
2. Remove the plasterboard and/or brick work to
a minimum depth of 62 mm.
62 mm Min
24 mm Max
Finished Wall
4 mm Min
Finished Wall
Finished Wall
Surface
Securing
Bracket
3. Fit the securing brackets to the mixer with the
bracket securing screws.
Important! Make sure that the correct holes
are used, otherwise the backplate cannot be
tted.
Backplate
Securing Holes
Countersunk
Fixing Hole
4. Make sure that the mixer is level and mark the
positions for the countersunk xing holes on
the wall.
5.
For solid walls drill two 6 mm holes for the wall
plugs.
6. Fit the hot and cold supply pipework (Hot -
Left, Cold - Right).
7. Caution! It is essential at this point
that the supply pipework is thoroughly
ushedthroughbeforeconnectiontothe
mixer. Failure to do so may result in product
malfunction and will not be covered under the
guarantee.
8.
Remove the wall brackets from the mixer.
9. Make sure that the olives are tted, connect
the hot and cold supply pipes and tighten the
compression nuts.
10.
Ret the wall brackets to the mixer, t the wall
plugs and x the mixer to the wall with the
screws provided.
Note! For stud partition installations alternative
xings may be required (not supplied).
14. Connect the outlet pipework and install the
RAC assembly or BIR assembly, before
continuing with the installation of the mixing
valve.
RAC assembly, go to section: ‘Installation,
RAC Assembly’.
BIR assembly, refer to your shower ttings
installation and user guide then continue with
instruction 12.
Screws
Outlet Pipe
to Fittings
Hot Supply
Cold Supply
12. Turn on the water supplies and check for
leaks