7. Wiring and Connection
7 - 4
7-2 Main circuit and control circuit connectors
Do not apply a voltage other than that specified on each terminal. Failure to
observe this item could lead to rupture or damage, etc.
CAUTION
7-2-1 Connector pin assignment
Unit
Terminal
MDS-R-V1-
MDS-R-V2-
Connector position
(a)
(d)
(b)
(c)
(a)
(b)
(d)
(a) CN30
(DDK)
Housing : DK-5200M-06R
Contact : DK-5RECSLP1-100 for AWG14,16
Contact : DK-5RECMLP1-100 for AWG10,12
(b)
(c)
CN31L
CN31M
(DDK)
Housing : DK-5200M-04R
Contact : DK-5RECSLP1-100 for AWG14,16
Contact : DK-5RECMLP1-100 for AWG10,12
Terminal
specification/
Pin
assignment
(d) CN22
(DDK)
Housing : DK-3200S-02R
Contact : DK-3REC2LLP1-100 for AWG14
L1 L2 L3
B
A
P C PE
U W
B
A
V PE
1
VDD
SG
2