EasyManua.ls Logo

Mitsubishi Electric MELDAS MDS-R Series - Contactor Control Signal (MC) Output Circuit

Mitsubishi Electric MELDAS MDS-R Series
362 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7. Wiring and Connection
7 - 15
7-7-2 Contactor control signal (MC) output circuit
A relay or photo coupler can be driven. When using an inductive load, install a diode.
(Tolerable current: 40mA or less, rush current: 100mA or less)
When using an internal power supply
When using an external power supply
Contactor
MDS-R-V1/V2
10 VDD
5 COM
15 MC
3 SG
CN9
Contactor control relay
(There are also types that
are built into the contactor.)
24VDC
T
he ser
vo drive unit will
fail if the diode polarity is
incorrect.
Contactor
MDS-R-V1/V2
10 VDD
5 COM
15 MC
3 SG
CN9
27VDC
or less
24VDC
Contactor control relay
(There are also ty
pes that
are built into the contactor.)
The servo drive unit will
fail if the diode polarity is
incorrect.
When using the internal power supply, the power can be directly connected to
VDD if using only the digital output (MC, MBR). When using the digital input
(EMGX), always connect across VDD-COM.
POINT
Downloaded from ManualsNet.com search engine

Table of Contents

Other manuals for Mitsubishi Electric MELDAS MDS-R Series

Related product manuals