Appendix 1. Cable and Connector Specifications
A1 - 7
(4) Rectangular wave communication detector (linear scale, etc.) cable connection diagram
1
2
10
3
4
5
6
7
8
9
PE
P5(+5V)
LG
ABZSEL*
A
A*
B
B*
Z
Z*
P5(+5V)
LG
A
A*
B
B*
Z
Z*
SHD
0.5mm
2
0.5mm
2
0.2mm
2
Contact the detector manufacture
for the details.
Note: Contact the detector
manufacture about whether
to perform the P5V wiring or
not.
Servo drive unit side connecto
r
(3M)
Receptacle: 36210-0100JL
Shell kit: 36310-3200-008
Molex
Connector set: 54599-1019
Case
grounding
0.2mm
2
0.2mm
2
(Note) This cable must be prepared by the user.