Appendix 1. Cable and Connector Specifications
A1 - 17
(6) Back clamp nut tightening, shell tightening
[1] Temporarily tighten the back shell coupling on the straight back shell.
* To prevent loosening, the adhesive should be applied to the straight back shell.
[2] Set the back shell wrench on the back shell coupling.
[3] With the wrench, tighten the back shell coupling on the straight back shell.
Recommended tightening: 5Nm
(Note) Accurately fit the wrench on the back shell coupling.
To remove, take the reverse steps.
* Recommendation Adhesive (2 threads around the circumference)
Temporary tightening
Back shell coupling
Back shell
Tightening guide
Set
Tightening guide
Back shell
wrench
Tighten
Back shell
wrench
19
17
* Referential dimensions for
back shell tightening guide
(Back shell width)
20
Thickness:
10
* Recommendation:
Tightening guide
(357J-50494T)
Recommended jigs and toolsBack shell wrench (357J-51333T)
Bit (357J-51344T)
Torque wrench (CL6N x 8D,Tonichi Mfg.)
* Recommended tightening guide: (357J-50494T)
* Recommended adhesive: screw lock 1401B (Threee bond Co,Ltd)