EasyManua.ls Logo

Mitsubishi Electric MELDAS MDS-R Series - Page 260

Mitsubishi Electric MELDAS MDS-R Series
362 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Appendix 1. Cable and Connector Specifications
A1 - 19
(8) Tightening a clamp nut
[1] Temporarily tighten the clamp nut on the back shell.
* To prevent loosening, the adhesive should be applied to the back shell.
[2] Set the clamp nut wrench on the clamp nut.
[3] With the wrench, tighten the clamp nut on the straight back shell.
Recommended tightening: 5Nm
(Note) Accurately fit the wrench on the clamp nut.
To remove, take the reverse steps.
* Recommendation
Adhesive (2 threads around
the circumference)
Temporary tightening
Set
Tightening guide
Torque wrench
Tighten
Clamp nut
wrench
19
17
* Referential dimensions for back
shell tightening guide
(Back shell width)
20
Thickness
:10
* Recommendation :
Tightening guide
(357J-50494T)
Recommended jigs and tools : Clamp nut wrench(357J-51334T)
Bit (357J-51345T)
Torque wrench (CL6N x 8D, Tonichi Mfg.)
* Recommended tightening jig : (357J-50494T)
Back shell
Clamp nut
Tightening guide
* Recommended adhesive : Screw lock 1401B (Three Bond Co,.Ltd)