FX communication
RS instruction 9
9-18
4 ) Operation
Turn on the power of the
programmable controller and printer,
check the printer is on line and switch
the programmable controller to RUN.
Turn on X000, and drive RS
instruction.
Every time X001 is turned on, the
contents of D200 to D210 are sent
to the printer, and "test line" is
printed.
Power on
RS instruction
drive
Data send
X000,ON
X001,ON
In this example,CR (H000D) and
LF (H000A) are written at the
end of the message. The printer
moves down one line for each
meessage.
CR: Carriage Return
LF: Line Feed
·
Note:lt may be necessary to set
the DIP switches of your printer.
Check your printer manual for
how to configure the serial
communications.