5 SAFETY APPLICATION CONFIGURATION EXAMPLES
5.2 System to Which Multiple Safety CPUs are Connected
221
5
This example shows when the guard open/close signal of the safety switch is input. When using a safety switch whose
interlock status can be monitored, input the locking status signal to the safety remote I/O module as well.
For safety switch and electromagnetic contactors, set the parameters as follows.
Item Setting details
*3
SR_M2IO1 SR_M3IO1 SR_M4IO1
Transmission interval monitoring time 24ms 24ms 24ms
Wiring selection of input X2 Double wiring (NC/NC)
*4
Double wiring (NC/NC)
*4
Double wiring (NC/NC)
*4
Wiring selection of input X3 Double wiring (NC/NC)
*4
Double wiring (NC/NC)
*4
Double wiring (NC/NC)
*4
Wiring selection of input X4 Double wiring (NC/NC)
*4
Double wiring (NC/NC)
*4
Double wiring (NC/NC)
*4
Wiring selection of input X5 Double wiring (NC/NC)
*4
Double wiring (NC/NC)
*4
Double wiring (NC/NC)
*4
Wiring selection of input X0, X1, and X6 to X1F Not used Not used Not used
Input response time X2
*1
1ms 1ms 1ms
Input response time X3
*1
1ms 1ms 1ms
Input response time X4
*1
1ms 1ms 1ms
Input response time X5
*1
1ms 1ms 1ms
Input response time X6
*1
1ms 1ms 1ms
Input response time X7
*1
1ms 1ms 1ms
Input response time X8
*1
1ms 1ms 1ms
Input response time X0, X1, and X9 to X1F
*1
1ms 1ms 1ms
Double input discrepancy detection setting X2_X3 Detect
*4
Detect
*4
Detect
*4
Double input discrepancy detection setting X4_X5 Detect
*4
Detect
*4
Detect
*4
Double input discrepancy detection setting X0, X1, and
X9 to X1F
Do not detect
*4
Do not detect
*4
Do not detect
*4
Double input discrepancy detection type X2_X3 Discrepancy detection time
specified
*4
Discrepancy detection time
specified
*4
Discrepancy detection time
specified
*4
Double input discrepancy detection type X4_X5 Discrepancy detection time
specified
*4
Discrepancy detection time
specified
*4
Discrepancy detection time
specified
*4
Double input discrepancy detection type X0, X1, and
X9 to X1F
Discrepancy detection time not
specified
*4
Discrepancy detection time not
specified
*4
Discrepancy detection time not
specified
*4
Double input discrepancy auto recovery setting Not used Not used Not used
Double input discrepancy detection time X2_X3
*2
10 (100ms) 10 (100ms) 10 (100ms)
Double input discrepancy detection time X4_X5
*2
50 (500ms) 50 (500ms) 50 (500ms)
Double input discrepancy detection time X0, X1, and
X9 to X1F
*2
1 (10ms) 1 (10ms) 1 (10ms)
Input dark test execution setting X2 Perform
*4
Perform
*4
Perform
*4
Input dark test execution setting X3 Perform
*4
Perform
*4
Perform
*4
Input dark test execution setting X4 Perform
*4
Perform
*4
Perform
*4
Input dark test execution setting X5 Perform
*4
Perform
*4
Perform
*4
Input dark test execution setting X0, X1, and X9 to X1F Do not perform
*4
Do not perform
*4
Do not perform
*4
Input dark test pulse OFF time
*1
400s400s400s
Number of pulse output for input dark test 1 time 1 time 1 time
Ext. module 1_Wiring selection of output Y0 Double wiring (Source/
Source)
*4
Double wiring (Source/
Source)
*4
Double wiring (Source/
Source)
*4
Ext. module 1_Wiring selection of output Y1 Double wiring (Source/
Source)
*4
Double wiring (Source/
Source)
*4
Double wiring (Source/
Source)
*4
Ext. module 1_Wiring selection of output Y2 Single wiring
*4
Single wiring
*4
Single wiring
*4
Ext. module 1_Wiring selection of output Y3 to Y7 Not used
*4
Not used
*4
Not used
*4
Ext. module 1_Output dark test execution setting Y0 Perform
*4
Perform
*4
Perform
*4
Ext. module 1_Output dark test execution setting Y1 Perform
*4
Perform
*4
Perform
*4
Ext. module 1_Output dark test execution setting Y2 Do not perform
*4
Do not perform
*4
Do not perform
*4
Ext. module 1_Output dark test execution setting Y3 to
Y7
Do not perform
*4
Do not perform
*4
Do not perform
*4
Ext. module 1_Output dark test pulse OFF time Y0
*1
1ms 1ms 1ms
Ext. module 1_Output dark test pulse OFF time Y1
*1
1ms 1ms 1ms
Ext. module 1_Output dark test pulse OFF time Y2
*1
1ms 1ms 1ms