4 PRECAUTIONS FOR USE OF SAFETY PROGRAMMABLE CONTROLLER
4.2 Precautions for Programming
39
4
Detecting errors in the CC-Link IE Field Network
Errors occurred in the CC-Link IE Field Network can be detected using safety refresh communication status. Create a
program using safety refresh communication status, which turns off safety outputs in case of an error.
Safety refresh communication status
The following table lists the special register names and numbers to check safety refresh communication status for each safety
connection. If multiple CC-Link IE Field Network master/local modules are connected to the base unit, the number of the
special register varies according to the number of modules connected. The safety connection number is the one displayed as
"No" on the detailed setting window of the safety communication in the CC-Link IE Field Network master/local module.
Name No. Description of bits of the special register areas (safety refresh
communication status)
Safety refresh communication status of
each safety connection (1st module)
SA\SD1008 to SA\SD1015 Description of bits of the following table
0: Safety communications normal, safety connection not used
1: Safety communication error
1 to 120: Safety connection numbers
: Fixed to 0.
Safety refresh status of each safety
connection (2nd module)
SA\SD1016 to SA\SD1023 Description of bits of the following table
0: Safety communications normal, safety connection not used
1: Safety communication error
1 to 120: Safety connection numbers
: Fixed to 0.
16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0
32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17
48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33
64 63 62 61 60 59 58 57 56 55 54 53 52 51 50 49
80 79 78 77 76 75 74 73 72 71 70 69 68 67 66 65
96 95 94 93 92 91 90 89 88 87 86 85 84 83 82 81
112 111 110 109 108 107 106 105 104 103 102 101 100 99 98 97
120 119 118 117 116 115 114 113
SA\SD1008
SA\SD1009
SA\SD1010
SA\SD1011
SA\SD1012
SA\SD1013
SA\SD1014
SA\SD1015
16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0
32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17
48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33
64 63 62 61 60 59 58 57 56 55 54 53 52 51 50 49
80 79 78 77 76 75 74 73 72 71 70 69 68 67 66 65
96 95 94 93 92 91 90 89 88 87 86 85 84 83 82 81
112 111 110 109 108 107 106 105 104 103 102 101 100 99 98 97
120 119 118 117 116 115 114 113
SA\SD1016
SA\SD1017
SA\SD1018
SA\SD1019
SA\SD1020
SA\SD1021
SA\SD1022
SA\SD1023