132
6 USING THE PROGRAMMABLE CONTROLLER CPU MONITORING FUNCTION
6.2 Programmable Controller CPU Monitoring Function
When user frame No. B061H is designated
Programmable controller CPU status information (for one block) is transmitted as the following data:
(When ASCII-BIN conversion is not performed)
The total number of bytes for the device data portion is the number of device points 2.
(When ASCII-BIN conversion is performed)
The total number of bytes for the device data portion is the number of device points 4.
When user frame No. B080H is designated
The transmission block is transmitted as follows.
Ex.
Number of registered word blocks: 2 (D0 to D3 (4 points), W100 to W107 (8 points))
Number of registered bit blocks : 1 (M0 to M31 (2 points))
Item Communicating with
ASCII code
Communicating with
binary code
Remarks
Device code '01' 01H All fixed value
Number of registered points '0001' 0001H
Monitoring start device '000000' 000000H
Device data During normal operation '0000' 0000H
Module warning occurring '0001' 0001H
Module error/module system error occurring '0002' 0002H
When the word/byte units designation is byte When the word/byte units designation is word
When the word/byte units designation is byte When the word/byte units designation is word
(When ASCII-BIN conversion is not performed) (When ASCII-BIN conversion is performed)
L H
L
H
L
H
01
H
00
H
00
H
00
H
01
H
00
H
01
H
00
H
Device code
Number of
registered points
Device data
Monitoring start
device
HL
L
H
L
H
01
H
00
H
00
H
00
H
01
H
00
H
00
H
01
H
Device code
Monitoring
start device
Number of
registered points
Device data
LHLHLHLH
1
00
0
0
0
0
00
0
1
0
1
00
0
30
H
31
H
30
H
30
H
30
H
30
H
30
H
30
H
30
H
30
H
30
H
31
H
30
H
31
H
30
H
30
H
Device data
Device code
Monitoring start
device
Number of
registered points
LHLHLHLH
1
00
0
00
0
0
00
0
1
0
0
01
0
30H 31H 30H 30H 30H 30H 30H 30H 30H 30H 30H 31H 30H 30H 30H 31H
Device data
Device code
Monitoring start
device
Number of
registered points
02H 01H 00H
Number of registered word
blocks
Number of registered bit blocks
CPU abnormal monitoring
LH
201000
LHLH
30H 32H 30H 31H 30H 30H
Number of registered
word blocks
Number of registered
bit blocks
CPU abnormal
monitoring