APPENDICES APPENDIX
Appendix 3 Buffer Memory
515
A
16518
(4086H)
Protocol setting
data error
information
Protocol No.
1 to 128: Protocol No.
65535: Unidentified
0 R Page 35 Packet
elements
Page 473 Error Code
List
16519
(4087H)
Setting type
0: Packet setting or element setting
1: Protocol detailed setting
65535: Unidentified
0
16520
(4088H)
Packet No.
0: Send packet
1 to 16: Receive packet No.
65535: Unidentified
Valid when the Setting type value is 0.
0
16521
(4089H)
Element No.
1 to 32: Element No.
65535: Unidentified
Valid when the Setting type value is 0.
0
16522 to 16527
(408AH to 408FH)
Use prohibited System area
16528
(4090H)
For confirmation
of protocol
setting data
Number of registered protocols
0: No registration
1 to 128: Number of registrations
0 R Page 26 DATA
COMMUNICATION
USING
PREDEFINED
PROTOCOL
16529 to 16536
(4091H to 4098H)
Protocol registration
0: No registration
1: Registered
The bit corresponding to each protocol No.
turns ON or OFF.
0
16537 to 16607
(4099H to 40DFH)
Use prohibited System area
16608,
16609
(40E0H,
40E21)
16624,
16625
(40F0H,
40F1H)
Use prohibited System area
16610
(40E2H)
16626
(40F2H)
For designation
of protocol
execution
history
Execution log options
History storage condition
0 (OFF): Error logs of only protocol that
completed abnormally are stored.
1 (ON): All protocol execution status and
execution logs are stored.
0 RW Page 113 Protocol
Execution Log
Storage Function (for
Predefined Protocol
only)
16611 to
16623
(40E3H
to
40EFH)
16627 to
16638
(40F3H to
40FEH)
Use prohibited System area
16639
(4
0FFH)
18431
(47FFH)
Use prohibited System area
Address
Dec (Hex)
Purpose Name Defaul
t value
Protocol Reference
CH1 CH2 MC Non Bi Pd
12341415
16
29303132
171819
45464748
333435
626364
495051
787980 656667
949596
818283
979899100
110111112
113114115116
126127128
b15
b14
b13 b2 b1 b0
* Each bit indicates the
corresponding protocol No.
Un\G16529
Un\G16530
Un\G16531
Un\G16532
Un\G16533
Un\G16534
Un\G16535
Un\G16536
0: Not registered
1: Registered

Table of Contents