2 - 31
2 SYSTEM CONFIGURATION
(3) Rotary switch assignment
(a) Rotary function select 1 switch (SW1)
Rotary switch
Setting
(Note)
Mode Description
D
0
8
C
4
F
E
B
A
9
6
7
5
3
2
1
0 Normal mode Normal operation mode
A Installation mode
Installed the operating system software using
MT Developer2
(Note): Do not set other than the above setting.
(b) Rotary function select 2 switch (SW2)
Rotary switch
Setting
(Note)
Mode Description
D
0
8
C
4
F
E
B
A
9
6
7
5
3
2
1
0 Mode operated by RAM
Normal operation mode
(Operation by the setting data and parameters
stored in the SRAM built-in Motion CPU module.)
6 Mode operated by ROM
Mode to operate based on the setting data and
parameters wrote to the FLASH ROM built-in
Motion CPU module.
8
Ethernet IP address
display mode
Mode to display the Ethernet IP address.
C SRAM clear SRAM "0" clear
(Note): Do not set other than the above setting.
CAUTION
Be sure to turn OFF the Multiple system power supply before the rotary switch setting change.
(4) Operation mode
(a) Rotary switch setting and operation mode
Rotary switch setting
(Note-1)
Operation mode
SW1 SW2
A Any setting (Except C) Installation mode
0 0 Mode operated by RAM
0 6 Mode operated by ROM
0 8 Ethernet IP address display mode
Any setting C SRAM clear
(Note-2)
(Note-1): Do not set other than the above setting.
(Note-2): The programs, parameters, motion devices(#), devices of latch data and absolute