What does SSCNET receive error 2 mean on Mitsubishi Electric MELSERVO-J4?
- CCorey TorresSep 8, 2025
An SSCNET receive error 2 on your Mitsubishi Electric Amplifier indicates a continuous communication data error.
What does SSCNET receive error 2 mean on Mitsubishi Electric MELSERVO-J4?
An SSCNET receive error 2 on your Mitsubishi Electric Amplifier indicates a continuous communication data error.
What does a cooling fan error mean on a Mitsubishi Electric MELSERVO-J4 Amplifier?
A cooling fan error in your Mitsubishi Electric Amplifier may be due to a cooling fan stop error or a cooling fan speed reduction error.
What does servo control error mean on Mitsubishi Electric MELSERVO-J4 Amplifier?
A servo control error in your Mitsubishi Electric Amplifier can be caused by: * Servo control error by position deviation. * Servo control error by speed deviation. * Servo control error by torque/thrust deviation. * Fully closed loop control error by position deviation. * Fully closed loop control error by speed deviation. * Fully closed loop control error by position deviation (during command stop).
What causes a parameter setting error for driver communication on Mitsubishi Electric MELSERVO-J4 Amplifier?
A parameter setting error for driver communication on your Mitsubishi Electric Amplifier can be caused by a parameter combination error for driver communication on either the slave or the master.
What causes option card error 2 on Mitsubishi Electric MELSERVO-J4 Amplifier?
An option card error 2 on your Mitsubishi Electric Amplifier can be caused by an option card connection error or the option card being disconnected.
What does a clock error mean on a Mitsubishi Electric MELSERVO-J4 Amplifier?
A clock error on your Mitsubishi Electric Amplifier could be due to clock error 1 or clock error 2.
What causes an overload 1 error in Mitsubishi Electric MELSERVO-J4?
An overload 1 error in your Mitsubishi Electric Amplifier can occur due to: * Thermal overload error 1 during operation. * Thermal overload error 2 during operation. * Thermal overload error 4 during operation. * Thermal overload error 1 during a stop. * Thermal overload error 2 during a stop. * Thermal overload error 4 during a stop.
Why does my Mitsubishi Electric MELSERVO-J4 show a regenerative error?
A regenerative error in your Mitsubishi Electric Amplifier can be caused by: * Regeneration heat error. * Regeneration signal error. * Regeneration feedback signal error.
Why is my Mitsubishi Electric MELSERVO-J4 Amplifier showing an Undervoltage error?
An undervoltage error in your Mitsubishi Electric Amplifier may be due to a voltage drop in either the control circuit power or the main circuit power.
What causes overcurrent in Mitsubishi Electric MELSERVO-J4?
Overcurrent in the Mitsubishi Electric Amplifier can be caused by: * Overcurrent detected at the hardware detection circuit during operation. * Overcurrent detected at the software detection function during operation. * Overcurrent detected at the hardware detection circuit during a stop. * Overcurrent detected at the software detection function during a stop.
Series | MELSERVO-J4 |
---|---|
Full-closed Control | Supported |
Advanced One-touch Tuning | Supported |
Real-time Adaptive Tuning | Supported |
Vibration Suppression Control | Supported |
Communication Interface | SSCNET III/H |
Safety Functions | STO (Safe Torque Off), SS1 (Safe Stop 1), SS2 (Safe Stop 2), SBC (Safe Brake Control) |
Protection Functions | Overcurrent, Overvoltage, Overload, Overheat, Encoder Error, Regenerative Error |
Ambient Temperature | 0°C to +55°C |
Vibration Resistance | 5.9 m/s² (0.6G) at 10 to 55 Hz |
Feedback System | Absolute/Incremental Encoder, Resolver |