8 - 7
EMC AND LOW VOLTAGE DIRECTIVES8.
(b) When connecting a cable longer than 2m, but not exceeding 10m
Ground the shield section of the external wiring cable with a cable clamp.
(Ground the shield at the closest location to the A1SD75-S3 external wiring
connector.)
Install a ferrite core.
Connect the external wiring cable to a drive unit or an external device in the
shortest distance.
(c) Models and required quantities of the ferrite core and cable clamp
Cable clamp
Ferrite core
Required quantity
(d) Cable clamp position
Model: AD75CK (manufactured by Mitsubishi Electric Corporation)
Model: ZCAT3035-1330 (manufactured by TDK Corporation)
Contact: TDK Corporation
Cable Length Optional Part
Required Quantity
1 axis 2 axes 3 axes
Within 2m AD75CK 1 1 1
2m to 10m
AD75CK 1 1 1
ZCAT3035-1330 1 2 3
A1SD75
AD75CK
Inside control panel
20 to 30cm