11 - 6
11. TROUBLESHOOTING
11.2.5 Flow for actions when the RUN LED is flashing
The corrective action when the RUN LED is flashing during power on, start of the 
operation, or during operation is described.
NO
YES
The RUN LED
is flashing.
Confirm the error details
from the peripheral device.
(Refer to                     .)
Hardware error
Describe the problem to the
nearest service center, retail
store, or corporate office, and
obtain advice.
Reset the CPU module
using the RESET/L.CLR 
switch.
Correct the error details.
(Refer to                     .)
Set the RUN/STOP
switch to the "RUN" 
position.
Does the
RUN LED
turn on?
Complete