Mitsubishi Electric QD62D User Manual

Mitsubishi Electric QD62D
128 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image

Table of Contents

Questions and Answers:

Mitsubishi Electric QD62D Specifications

General IconGeneral
TypeHigh-Speed Counter Module
Weight0.2 kg
Product SeriesMELSEC-Q
Number of Channels2 channels
Input Voltage Range5 to 24 V DC
Counter ModesLinear, Ring
Occupied Slots1
Power Supply5V DC
Count Range-2147483648 to +2147483647
Input SignalDifferential input, Open collector input

Summary

SAFETY PRECAUTIONS

Design Precautions

Discusses DANGER and CAUTION points for module design and system setup.

Installation Precautions

Details precautions for mounting modules, tightening screws, and handling components.

Wiring Precautions

Covers precautions for connectors, foreign matter, and cable management during wiring.

Startup and Maintenance Precautions

Outlines precautions for module startup, cleaning, and handling to prevent damage or failure.

2 SYSTEM CONFIGURATION

3 SPECIFICATIONS

3.1 Performance Specifications

Lists the detailed performance specifications for the QD62 (DC input sinking output type).

QD62E Performance Specifications

Lists the detailed performance specifications for the QD62E (DC input sourcing output type).

QD62D Performance Specifications

Lists the detailed performance specifications for the QD62D (Differential input sinking output type).

4 SETUP AND PROCEDURE BEFORE STARTING THE OPERATION

4.1 Handling Precautions

Lists important precautions for safely handling the QD62(E/D) module.

5 BASIC USAGE

7 UTILITY PACKAGE (GX Configurator-CT)

8 PROGRAMMING

8.1 Using Programs in Normal System Configuration

Provides program examples for normal system configurations with the QD62(E/D).

8.1.1 Program Example when GX Configurator-CT is Used

Details a program example using GX Configurator-CT for QD62(E/D) operations.

8.1.2 Program Example when GX Configurator-CT is Not Used

Provides a program example for QD62(E/D) operations without using GX Configurator-CT.

8.2 Using Programs on Remote I/O Network

Describes program examples for QD62(E/D) used in remote I/O network configurations.

8.2.1 Program Example when GX Configurator-CT is Used

Details a program example for remote I/O network configurations using GX Configurator-CT.

8.2.2 Program Example when GX Configurator-CT is Not Used

Provides a program example for remote I/O network without GX Configurator-CT.

9 TROUBLESHOOTING

9.1 Error Information

Lists and explains error information detected by the QD62(E/D) and their corresponding actions.

9.2 When the QD62(E/D) Does Not Start Counting

Provides troubleshooting steps for issues when the QD62(E/D) fails to start counting.

9.3 When the QD62(E/D) Does Not Normally Count

Offers troubleshooting steps for when the QD62(E/D) does not count normally.

Related product manuals