2 - 16
SYSTEM CONFIGURATION2.
MELSECNET/10
data link
module
A1SJ71LP21
For the control, master, and normal stations of
the MELSECNET/10 data link module system
(For the dual loop SI-type optical fiber cable)
32
[32 special
points]
0.65
A1SJ71LP21GE
For the control, master, and normal stations of
the MELSECNET/10 data link module system
(For the dual loop GI-type optical fiber cable)
32
[32 special
points]
0.65
A1SJ71BR11
For the control, master, and normal stations of
the MELSECNET/10 data link module system
(For the single bus coaxial cable)
32
[32 special
points]
0.80
A1SJ71LR21
For the control, master, and normal stations of
the MELSECNET/10 data link module system
(For the coaxial cable dual loop)
32
[32 special
points]
1.14
CC-Link system
master module
A1SJ61BT11
For the master and local stations of the CC-Link
data link system
(For the twisted pair shield cable only)
32
[32 special
points]
0.40
MELSECNET/
MINI-S3 master
module
A1SJ71PT32-S3
For MELSECNET/MINI-S3 master stations
(max. 64 stations). Performs remote I/O and
remote terminal control of a total of 512 I/O
points.
I/O mode
32 [32 special points]
0.35
Expanded mode
48 [48 special points]
MELSECNET-I/
O LINK master
module
A1SJ51T64
MELSECNET-I/O LINK master station. Controls
I/O LINK remote I/O module of a maximum of
64 stations and a total of 128 I/O points.
If only a few remote I/O modules are used,
perform I/O assignment with a peripheral device
to decrease the number of occupied I/O points
to 16, 32, or 48.
64
[64 output
points]
0.115 0.09
S-LINK
interface
module
A1SJ71SL92N
Master module for S-LINK
I/O total 128 points
32
[32 special
points]
0.20
AS-I interface
module
A1SJ71AS92
Master module for AS-I
I/O total 496 points
32
[32 special
points]
0.15
Positioning
detection
module
A1S62LS Absolute positioning detection module 32
[32 special
points]
0.55
Programmable
controller easier
monitoring
module
A1SS91
Programmable controller easier monitoring
module
16
[16 output
po
ints]
0.08
Memory card
interface
module
A1SD59J-S2 Memory card interface module 32
[32 special
points]
0.05
The current
consumption
describes in
connecting
A1SD59J-MIF.
Simulation
module
A6SIM-X64Y64
An I/O simulation module used connected to the
base unit Debugging can be executed without
connecting the I/O module to the base unit. Use
an extension cable of the AnS series between
the main base of the AnS series and the
A6SIM-X64Y64.
64
64
[64 input points]
[64 output
points]
TYP. 0.3
(When all
points
"ON")
Product Name Model Name Description
Number of Occupied
Points (points)
[I/O Assignment
Module Type]
Current Consumption
Remark
5VDC(A) 24VDC(A)

Table of Contents

Related product manuals