461
APPENDICES
A
Appendix 2 List of Special Relay Areas
SM254
All stations refresh
command
OFF: Refresh arrival
station
ON: Refresh all
stations
Effective for the batch refresh (also
effective for the low speed cyclic)
Designate whether to receive arrival
stations only or to receive all slave
stations in the MELSECNET/H.
UNew
Qn(H)
QnPH
QnPRH
Effective for the batch refresh (also
effective for the low speed cyclic)
Designate whether to receive arrival
stations only or to receive all slave
stations in the CC-Link IE Controller
Network.
Qn(H)
*2
QnPH
QnPRH
Effective for the batch refresh (also
effective for the low speed cyclic)
Specify whether to receive only arrival
station or all stations in the
MELSECNET/H or CC-Link IE
Controller Network.
QnU
SM255
MELSECNET/10,
MELSECNET/H
module 1
information
OFF: Operative
network
ON: Standby network
Turns on when it belongs to the standby
network. (If no specification has been
made, it is set to the operative network.)
S (Initial)
New
Qn(H)
QnPH
QnPRH
SM256
OFF: Reads
ON: Does not read
For refresh from the network module to
the CPU module, set whether to read
data from the network module to a device
(such as B and W) or not.
U
SM257
OFF: Writes
ON: Does not write
For refresh from the CPU module to the
network module, set whether to write
data in a device (such as B and W) to the
network module or not.
SM260
MELSECNET/10,
MELSECNET/H
module 2
information
OFF: Operative
network
ON: Standby network
Turns on when it belongs to the standby
network. (If no specification has been
made, it is set to the operative network.)
S (Initial)
New
Qn(H)
QnPH
QnPRH
SM261
OFF: Reads
ON: Does not read
For refresh from the network module to
the CPU module, set whether to read
data from the network module to a device
(such as B and W) or not.
U
SM262
OFF: Writes
ON: Does not write
For refresh from the CPU module to the
network module, set whether to write
data in a device (such as B and W) to the
network module or not.
SM265
MELSECNET/10,
MELSECNET/H
module 3
information
OFF: Operative
network
ON: Standby network
Turns on when it belongs to the standby
network. (If no specification has been
made, it is set to the operative network.)
S (Initial)
New
Qn(H)
QnPH
QnPRH
SM266
OFF: Reads
ON: Does not read
For refresh from the network module to
the CPU module, set whether to read
data from the network module to a device
(such as B and W) or not.
U
SM267
OFF: Writes
ON: Does not write
For refresh from the CPU module to the
network module, set whether to write
data in a device (such as B and W) to the
network module or not.
SM270
MELSECNET/10,
MELSECNET/H
module 4
information
OFF: Operative
network
ON: Standby network
Turns on when it belongs to the standby
network. (If no specification has been
made, it is set to the operative network.)
S (I
nitial)
New
Qn(H)
QnPH
QnPRH
SM271
OFF: Reads
ON: Does not read
For refresh from the network module to
the CPU module, set whether to read
data from the network module to a device
(such as B and W) or not.
U
SM272
OFF: Writes
ON: Does not write
For refresh from the CPU module to the
network module, set whether to write
data in a device (such as B and W) to the
network module or not.
Number Name Meaning Explanation
Set by
(When Set)
Corresponding
ACPU
M9
Corresponding
CPU

Table of Contents

Related product manuals