499
APPENDICES
A
Appendix 2 List of Special Relay Areas
SM1868
Axis 2 start
instruction
OFF: Not executed
ON: Being executed
This relay turns on when positioning
control by the start instruction
(IPPSTRT2(P), IPDSTRT2(P),
IPSIMUL(P), IPABRST2), JOG operation
by the JOG start instruction (IPJOG2), or
OPR control by the OPR start instruction
(IPOPR2(P)) is started.
This relay turns off when positioning
control, OPR control, or JOG operation is
completed.
S
(Instruction
execution/
Status
change)
New LCPU
SM1870
Axis 2 error
reset
OFF ON:Resets the
Axis 2 error.
OFF: Clears the reset
status.
Turning on this relay will turn off SM1865
and SM1866 and will clear the SD1865
and SD1866 values to "0".
Even if this relay is turned on, SM1865
will not turn off and the SD1865 value will
not be cleared to "0" until SM1860 turns
off.
UNewLCPU
SM1871
Axis 2 OPR
request off
OFF ON:Axis 2 OPR
request
OFF: Cleared
Turning on this relay will forcibly turn off
SM1862.
UNewLCPU
SM1872
Axis 2
speed/position
switching
OFF: Disabled
ON: Enabled
This relay stores whether to enable
switching from speed control to position
control in speed/position switching control.
UNewLCPU
SM1880
CH1 counter
value greater
(No.1)
OFF: Coincidence point
(No.1) or smaller
ON: Greater than
coincidence point
(No.1)
This relay turns on when "current value of
CH1 > coincidence output No.1 point
setting value" is met.
This relay turns off when "current value of
CH1 coincidence output No.1 point
setting value" is met.
S (Every
END
processing)
New LCPU
SM1881
CH1 counter
value
coincidence
(No.1)
OFF: Not detected
ON: Detected
This relay turns on when "current value of
CH1 = coincidence output No.1 point
setting value" is met.
This relay is turned off by turning on CH1
coincidence signal No.1 reset command.
S (Status
change/
Every END
processing)
New LCPU
SM1882
CH1 counter
value smaller
(No.1)
OFF: Coincidence point
(No.1) or greater
ON: Smaller than
coincidence point
(No.1)
This relay turns on when "current value of
CH1 <
coincidence output No.1 point
setting value" is met.
This relay turns off when "current value of
CH1 coincidence output No.1 point
setting value" is met.
S (Every
END
processing)
New LCPU
SM1883
CH1 counter
value greater
(No.2)
OFF: Coincidence point
(No.2) or smaller
ON: Greater than
coincidence point
(No.2)
This relay turns on when "current value of
CH1 > coincidence output No.2 point
setting value" is met.
This relay turns off when "current value of
CH1 coincidence output No.2 point
setting value" is met.
S (Every
END
processing)
New LCPU
SM1884
CH1 counter
value
coincidence
(No.2)
OFF: Not detected
ON: Detected
This relay turns on when "current value of
CH1 = coincidence output No.2 point
setting value" is met.
This relay is turned off by turning on CH1
coincidence signal No.2 reset command.
S (Status
change/
Every END
processing)
New LCPU
SM1885
CH1 counter
value smaller
(No.2)
OFF: Coincidence point
(No.2) or greater
ON: Smaller than
coincidence point
(No.2)
This relay turns on when "current value of
CH1 < coincidence output No.2 point
setting value" is met.
This relay turns off when "current value of
CH1 coincidence output No.2 point
setting value" is met.
S (Every
END
processing)
New LCPU
SM1886
CH1 external
preset (phase Z)
request
detection
OFF: Not detected
ON: Detected
This relay turns on when a preset request
by phase Z (preset) terminal of CH1 is
detected.
This relay is turned off by turning on CH1
external preset (phase Z) request
detection clear command.
S (Every
END
processing)
New LCPU
Number Name Meaning Explanation
Set by
(When Set)
Corresponding
ACPU
M9
Corresponding
CPU