578
SD1453
Error cause in a
device (iQ Sensor
Solution
backup/restoration)
Stores the cause of
the
backup/restoration
error detected in a
device.
This register stores the cause of the
backup/restoration error detected in a device.
• When errors are detected in multiple devices,
the error detected first is stored.
• A value is cleared to "0" when the right is
acquired.
For details on the cause of the error that is
stored, refer to the following.
iQ Sensor Solution Reference Manual
S
(Error/Status
change)
New
QnUDV
*1
LCPU
*2
SD1454
Error
module/execution
unit information (iQ
Sensor Solution
backup/restoration)
Stores the module
and execution unit
information when a
backup/restoration
error occurs.
This register stores the module and execution
unit information when a backup/restoration error
occurs.
Lower 8 bits (target module)
1
H
: AnyWireASLINK
2
H
: CC-Link
3
H
: Ethernet
4
H
: CC-Link IE Field Network
Upper 8 bits (execution unit)
1
H
: AnyWireASLINK
2
H
: CC-Link
3
H
: Ethernet
4
H
: CC-Link IE Field Network
[AnyWireASLINK]
1
H
: Module
2
H
: ID
[CC-Link, CC-Link IE Field Network]
1
H
: Module
2
H
: Station
3
H
: Station sub-ID
[Ethernet]
1
H
: Module
2
H
: IP address
• A value is cleared to "0" when the right is
acquired.
S
(Error/Status
change)
New
QnUDV
*1
LCPU
*2
SD1455
Error folder number
information (iQ
Sensor Solution
backup/restoration)
Stores the target
folder number
when a
backup/restoration
error occurs.
This register stores the target folder number (0
to 99) when a backup/restoration error occurs.
• When the folder number cannot be identified,
FFFF
H
is stored.
• A value is cleared to "0" when the right is
acquired.
S
(Error/Status
change)
New
QnUDV
*1
LCPU
*2
SD1456
Error module
information (iQ
Sensor Solution
backup/restoration)
Stores the
information of a
module where a
backup/restoration
error is detected
first.
This register stores the information of a module
where a backup/restoration error occurs.
I/O No.: Module (Enter the value obtained by
dividing the start I/O number by 16.)
3FF
H
: Built-in Ethernet
• When errors are detected in multiple devices,
the information of a module where the error
detected first is stored.
• A value is cleared to "0" when the right is
acquired.
S
(Error/Status
change)
New
QnUDV
*1
LCPU
*2
Number Name Meaning Explanation
Set by
(When Set)
Corresponding
ACPU
D9
Corresponding
CPU