EasyManua.ls Logo

Mitsubishi Electric Q13UDVCPU - Page 580

Mitsubishi Electric Q13UDVCPU
720 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
578
SD1453
Error cause in a
device (iQ Sensor
Solution
backup/restoration)
Stores the cause of
the
backup/restoration
error detected in a
device.
This register stores the cause of the
backup/restoration error detected in a device.
When errors are detected in multiple devices,
the error detected first is stored.
A value is cleared to "0" when the right is
acquired.
For details on the cause of the error that is
stored, refer to the following.
iQ Sensor Solution Reference Manual
S
(Error/Status
change)
New
QnUDV
*1
LCPU
*2
SD1454
Error
module/execution
unit information (iQ
Sensor Solution
backup/restoration)
Stores the module
and execution unit
information when a
backup/restoration
error occurs.
This register stores the module and execution
unit information when a backup/restoration error
occurs.
Lower 8 bits (target module)
1
H
: AnyWireASLINK
2
H
: CC-Link
3
H
: Ethernet
4
H
: CC-Link IE Field Network
Upper 8 bits (execution unit)
1
H
: AnyWireASLINK
2
H
: CC-Link
3
H
: Ethernet
4
H
: CC-Link IE Field Network
[AnyWireASLINK]
1
H
: Module
2
H
: ID
[CC-Link, CC-Link IE Field Network]
1
H
: Module
2
H
: Station
3
H
: Station sub-ID
[Ethernet]
1
H
: Module
2
H
: IP address
A value is cleared to "0" when the right is
acquired.
S
(Error/Status
change)
New
QnUDV
*1
LCPU
*2
SD1455
Error folder number
information (iQ
Sensor Solution
backup/restoration)
Stores the target
folder number
when a
backup/restoration
error occurs.
This register stores the target folder number (0
to 99) when a backup/restoration error occurs.
When the folder number cannot be identified,
FFFF
H
is stored.
A value is cleared to "0" when the right is
acquired.
S
(Error/Status
change)
New
QnUDV
*1
LCPU
*2
SD1456
Error module
information (iQ
Sensor Solution
backup/restoration)
Stores the
information of a
module where a
backup/restoration
error is detected
first.
This register stores the information of a module
where a backup/restoration error occurs.
I/O No.: Module (Enter the value obtained by
dividing the start I/O number by 16.)
3FF
H
: Built-in Ethernet
When errors are detected in multiple devices,
the information of a module where the error
detected first is stored.
A value is cleared to "0" when the right is
acquired.
S
(Error/Status
change)
New
QnUDV
*1
LCPU
*2
Number Name Meaning Explanation
Set by
(When Set)
Corresponding
ACPU
D9
Corresponding
CPU

Table of Contents

Related product manuals