EasyManua.ls Logo

Mitsubishi EHST20D-YM9C - Water System Diagrams

Mitsubishi EHST20D-YM9C
108 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
11
8
27
19
20
18
17
3
4
25
28
7
12
26
5
15
13
29
23
14
6
7
24
Pa
10
9
B
A
30
31
31
30
*1
16
Pa
11
10
8
27
19
9
16
20
B
A
30
*1
32
32
33
18
17
30
30
35
37
21
3
4
25
28
7
5
15
13
29
23
32
14
6
7
24
36
12
26
38
WATER SYSTEM DIAGRAM
8
•Refer to <Table 4-1 and 4-2> for the part names.
*1Refertothefollowingsection[Localsystem].
<E*ST20*-*M**C > (Split model system)
<EHST20*-MHCW>(UKSplitmodelsystem)<Example>
<Figure8-2>
<Figure8-1>
Notes:
•Toenabledrainingofthecylinderunit
an isolating valve should be posi-
tioned on both the inlet and outlet
pipework.
•Besuretoinstallastrainerontheinlet
pipeworktothecylinderunit.
•Suitabledrainpipeworkshouldbeat-
tached to all relief valves in accord-
ancewithyourcountry’sregulations.
•Abackowpreventiondevicemustbe
installed on the cold water supply
pipework(IEC61770)
• When using components made from
different metals or connecting pipes
made of different metals insulate the
joints to prevent any corrosive reac-
tion taking place which may damage
thepipework.
Flare connection
Flare connection
Cylinder unit
Cylinder unit
Drain
Drain
Drain
Drain
Drain
Drain
Coldwater
Coldwater
DHW
DHW
Local system
Refrigerantpipe
Water pipe
Local system
Flexiblehose
(Temporary connection)
Water
supply
Notes:
•
To enable drainingofthecylinderunit
anisolatingvalveshouldbepositioned
onboth the inlet and outlet pipework.
Novalveshouldbettedbetweenthe
expansionvalve(item35)andthecyl-
inder unit (safety matter).
•Besuretoinstallastrainerontheinlet
pipeworktothecylinderunit.
•Suitabledrainpipeworkshouldbeat-
tached to all relief valves in accord-
ancewithyourcountry’sregulations.
• When using components made from
different metals or connecting pipes
made of different metals insulate the
joints to prevent any corrosive reac-
tion taking place which may damage
anypipework.
•Fillingloop’sexiblehosemustbere-
movedfollowingthellingprocedure.
Item provided with unit as loose ac-
cessory.
•Installtheinletcontrolgroup(item35)
abovetheleveloftheT&Preliefvalve
(item21).Thiswillensure DHW tank
willnotrequiredrain-downtoservice/
maintaintheinletcontrolgroup.
Refrigerantpipe
Water pipe
OCH570C

Table of Contents