89
DRIVE THE MOTOR
3
Parameter list
Parameter List
Function assignment of input terminal
178
STF terminal
function selection
160
0 to 5, 7, 8,
10, 12, 14,
16, 18, 24,
25, 60∗1,
61∗2, 62,
65 to 67,
9999
0: Low-speed operation command (RL)
1: Middle-speed operation command (RM)
2: High-speed operation command (RH)
3: Second function selection (RT)
4: Terminal 4 input selection (AU)
5: JOG operation selection (JOG)
7: External thermal relay input (OH)
8: Fifteen speed selection (REX)
10: Inverter operation enable signal (X10)
(FR-HC/FR-CV connection)
12: PU operation external interlock (X12)
14: PID control valid terminal (X14)
16: PU-external operation switchover (X16)
18: V/F switchover (X18)
24: Output stop (MRS)
25: Start self-holding selection (STOP)
60: Forward rotation (STF) ∗1
61: Reverse rotation (STR) ∗2
62: Inverter reset (RES)
65: PU-NET operation switchover (X65)
66:
External-NET operation switchover (X66)
67: Command source switchover (X67)
9999: No function
∗1 Assigned to STF terminal (Pr. 178) only
∗2 Assigned to STR terminal (Pr. 179) only
×
179
STR terminal
function selection
161 ×
180
RL terminal
function selection
10 ×
181
RM terminal
function selection
11 ×
182
RH terminal
function selection
12 ×
Terminal assignment of output terminal
190
RUN terminal
function selection
10
0, 1, 3, 4,
7, 8,
11 to 16,
25, 26, 46,
47, 64, 70,
80, 81, 90,
91, 93∗1,
95, 96, 98,
99,
100, 101,
103, 104,
107, 108,
111 to 116,
125, 126,
146, 147,
164, 170,
180, 181,
190, 191,
193∗1,
195, 196,
198, 199,
9999∗2
0, 100: Inverter running (RUN)
1, 101: Up to frequency (SU)
3, 103: Overload alarm (OL)
4, 140: Output frequency detection (FU)
7, 107:
Regenerative brake pre-alarm (RBP)
8, 108: Electronic thermal relay function
pre-alarm (THP)
11, 111: Inverter operation ready (RY)
12, 112: Output current detection (Y12)
13, 113: Zero current detection (Y13)
14, 114: PID lower limit (FDN)
15, 115: PID upper limit (FUP)
16, 116: PID forward/reverse rotation
output (RL)
25, 125: Fan fault output (FAN)
26, 126: Heatsink overheat pre-alarm (FIN)
46, 164: During deceleration due to power
failure stop function (retained
until release) (Y46)
47, 147: During PID control activated (PID)
64, 164: During retry (Y64)
70, 170: PID output interruption (SLEEP)
80, 180: Safety monitor output (SAFE)
81, 181: Safety monitor output 2 (SAFE2)
90, 190: Life alarm (Y90)
91, 191:
Fault output 3 (power-off signal) (Y91)
93, 193: Current average value monitor
signal (Y93)∗1
95, 195: Maintenance timer signal (Y95)
96, 196: Remote output (REM)
98, 198: Alarm output (LF)
99, 199: Fault output (ALM)
9999, —: No function∗2
0 to 99: Positive logic
100 to 199: Negative logic
∗1 "93" and "193" cannot be set in Pr. 192.
∗2 "9999" cannot be set in Pr. 197.
×
192
A,B,C terminal
function selection
199 ×
197
SO terminal
function selection
180 ×
Function
Parameter
Name
Incre-
ments
Initial
Value
Range Description
Parameter
Copy
Parameter
Clear
All Parameter
Clear
Related
Parameter