EasyManua.ls Logo

Mitsubishi FR - S500 - Page 64

Mitsubishi FR - S500
196 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
54
Function (Parameter) list
Parameter List
Operation selection
functions
70
Soft-PWM
setting
Presence/absence of
Soft-PWM control can
be selected.
When Soft-PWM is
valid, the metallic tone
of motor noise can be
changed into
unoffending composite
tone.
0: Soft-PWM invalid
1: Soft-PWM valid
11103
71 Applied motor
0, 100:
Thermal characteristic
for Mitsubishi
standard motor
1, 101:
Thermal characteristic
for Mitsubishi
constant-torque motor
(Thermal characteristic
for Mitsubishi constant-
torque motor is
selected with the RT
signal ON when 100
and 101 are set.)
1069
72
PWM
frequency
selection
0 to 15 1 1 103
73
0-5V/0-10V
selection
0: For 0 to 5VDC input
1: For 0 to 10VDC input
10104
74
Input filter
time constant
0: 2-step moving
average processing
1 to 8:
Exponential
average value of 2n
at the setting of n
11105
Func-
tion
Para-
meter
Indica-
tion
Name Setting Range
Minimum
Setting
Increments
Factory
Setting
Refer
To:
Cus-
tomer
Setting

Table of Contents

Related product manuals