55
Function (Parameter) list
2
FUNCTIONS
Parameter List
Operation selection functions
75
Reset
selection/PU
stop selection
0: Reset normally
enabled/PU stop
key disabled
1: Enabled at alarm
occurrence only/PU
stop key disabled
14:Reset normally
enabled/normally
decelerated to stop
15: Enabled at alarm
occurrence only/
normally
decelerated to stop
114105
76
Cooling fan
operation
selection
0: Operation started at
power on
1: Cooling fan ON/
OFF control
11107
77
Parameter
write disable
selection
0: Write is enabled
only during a stop
1: Write disabled
(except some
parameters)
2: Write during
operation enabled
10108
78
Reverse
rotation
prevention
selection
0: Both forward
rotation and reverse
rotation enabled,
1: Reverse rotation
disabled,
2: Forward rotation
disabled
10109
Parameter 79 is basic function parameter.
Multi-speed operation function
80
Multi-speed
setting
(speed 8)
0 to 120Hz, - - - 0.1Hz - - - 66
81
Multi-speed
setting
(speed 9)
0 to 120Hz, - - - 0.1Hz - - - 66
82
Multi-speed
setting
(speed 10)
0 to 120Hz, - - - 0.1Hz - - - 66
83
Multi-speed
setting
(speed 11)
0 to 120Hz, - - - 0.1Hz - - - 66
Func-
tion
Para-
meter
Indica-
tion
Name Setting Range
Minimum
Setting
Increments
Factory
Setting
Refer
To:
Cus-
tomer
Setting

Table of Contents