56
Function (Parameter) list
Parameter List
Multi-speed operation function
84
Multi-speed
setting
(speed 12)
0 to 120Hz, - - - 0.1Hz - - - 66
85
Multi-speed
setting
(speed 13)
0 to 120Hz, - - - 0.1Hz - - - 66
86
Multi-speed
setting
(speed 14)
0 to 120Hz, - - - 0.1Hz - - - 66
87
Multi-speed
setting
(speed 15)
0 to 120Hz, - - - 0.1Hz - - - 66
PID control
88
PID action
selection
20: PID reverse action,
21: PID forward action
120113
89
PID
proportional
band
0.1 to 999%, - - - 0.1% 100% 113
90
PID integral
time
0.1 to 999s, - - - 0.1s 1s 113
91
PID upper
limit
0 to 100%, - - - 0.1% - - - 113
92
PID lower
limit
0 to 100%, - - - 0.1% - - - 113
93
PID action set
point for PU
operation
0 to 100% 0.01% 0% 113
94
PID
differential
time
0.01 to 10s, - - - 0.01s - - - 113
Slip compensation
95
Rated motor
slip
0 to 50%, - - - 0.01% - - - 120
96
Slip
compensation
time constant
0.01 to 10s 0.01s 0.5s 120
97
Constant-
output region
slip
compensation
selection
0, - - - 1 - - - 120
Automatic torque boost
98
Automatic
torque boost
selection
(Motor
capacity)
0.1 to 3.7kW, - - - 0.01kW - - - 121
99
Motor primary
resistance
0 to 50
, - - - 0.01 - - - 122
Func-
tion
Para-
meter
Indica-
tion
Name Setting Range
Minimum
Setting
Increments
Factory
Setting
Refer
To:
Cus-
tomer
Setting