Page #26 background imageLoading...
Page #26 background image
GENERAL
1-10
Electrical
system
Stop
solenoid (1)
Working voltage 12V - ETR: 8V or less
Insulation resistance
100 MΩ or more at DC 500 V megger
(normal temperature, normal relative humidity)
Stroke 13.5 ± 0.5 mm [0.53 ± 0.02 in.]
Ambient temperature for use -40 to 120°C [-40 to 248°F]
Stop
solenoid (2)
Working voltage 12V - ETS: 10 to 15V
Insulation resistance
100 MΩ or more at DC 500 V megger
(normal temperature, normal relative humidity)
Stroke 10 ± 0.5 mm [0.39 ± 0.02 in.]
Ambient temperature for use -30 to 120°C [-22 to 248°F]
Stop
solenoid (3)
Working voltage 24V - ETR: 16V or less
Insulation resistance
100 MΩ or more at DC 500V megger
(normal temperature, normal relative humidity)
Stroke 13.5 ± 0.5 mm [0.53 ± 0.02 in.]
Ambient temperature for use -40 to 120°C [-40 to 248°F]
Stop
solenoid (4)
Working voltage 24V - ETS: 20V to 30V
Insulation resistance
100 MΩ or more at DC 500V megger
(normal temperature, normal relative humidity)
Stroke 10 ± 0.5 mm [0.39 ± 0.02 in.]
Ambient temperature for use -30 to 120°C [-22 to 248°F]
Table 1-1 Specifications of L2A, L2C and L2E (4 / 4)
Engine model L2A L2C L2E

Table of Contents

Other manuals for Mitsubishi L3A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi L3A and is the answer not in the manual?

Mitsubishi L3A Specifications

General IconGeneral
BrandMitsubishi
ModelL3A
CategoryEngine
LanguageEnglish

Related product manuals