2 - 22
2. LINEAR SCALES
Linear encoder (linear scale) unit structure Reference
[When interpolator (MJ830) MODE switch = 5]
When PL101 or SL700 is used
SONY SL700
SONY
PL101R
Increasing direction Decreasing direction
When SH13 is used
Decreasing direction Increasing direction
SH13
Note 1. Note that the increasing direction/decreasing direction of the linear encoder (linear scale) changes depending on the setting of
the interpolator (MJ830).
2. Always set an encoder (scale) home position (reference mark).