14. COMMUNICATION FUNCTION
14 - 13
(4) Alarm history (command [3] [3])
Command Data No. Description Alarm occurrence sequence Frame length
[3] [3] [1] [0] Alarm No. in alarm history Most recent alarm 4
[1] [1] First alarm in past
[1] [2] Second alarm in past
[1] [3] Third alarm in past
[1] [4] Fourth alarm in past
[1] [5] Fifth alarm in past
[1] [6] Sixth alarm in past
[1] [7] Seventh alarm in past
[1] [8] Eighth alarm in past
[1] [9] Ninth alarm in past
[1] [A] Tenth alarm in past
[1] [B] Eleventh alarm in past
[1] [C] Twelfth alarm in past
[1] [D] Thirteenth alarm in past
[1] [E] Fourteenth alarm in past
[1] [F] Fifteenth alarm in past
[2] [0] Alarm occurrence time in alarm history Most recent alarm 8
[2] [1] First alarm in past
[2] [2] Second alarm in past
[2] [3] Third alarm in past
[2] [4] Fourth alarm in past
[2] [5] Fifth alarm in past
[2] [6] Sixth alarm in past
[2] [7] Seventh alarm in past
[2] [8] Eighth alarm in past
[2] [9] Ninth alarm in past
[2] [A] Tenth alarm in past
[2] [B] Eleventh alarm in past
[2] [C] Twelfth alarm in past
[2] [D] Thirteenth alarm in past
[2] [E] Fourteenth alarm in past
[2] [F] Fifteenth alarm in past
(5) Current alarm (command [0] [2])
Command Data No. Description Frame length
[0] [2] [0] [0] Current alarm No. 4