APPENDIX
App. - 15
App. 4.7 Transportation and storage
CAUTION
Transport the products correctly according to their mass.
Stacking in excess of the limited number of product packages is not allowed.
Do not hold the front cover to transport the servo amplifier. Otherwise, it may
drop.
Install the servo amplifier and servo motor in a load-bearing place in accordance
with the Instruction Manual.
Do not get on or put heavy load on the equipment.
For detailed information on the option battery’s transportation and handing, refer
to app. 2.
When you keep or use it, please fulfill the following environment.
Item Environment
Operation [°C] 0 to 55 Class 3K3 (IEC/EN 60721-3-3)
Ambient
temperature
Transportation (Note) [°C] -20 to 65 Class 2K4 (IEC/EN 60721-3-2)
Storage (Note) [°C] -20 to 65 Class 1K4 (IEC/EN 60721-3-1)
Ambient
humidity
Operation, transportation,
storage
5% to 90 %RH
Test values
10 Hz to 57 Hz with constant deviation of 0.075 mm
57 Hz to 150 Hz with constant acceleration of 9.8 m/s2 (1 g) to IEC/EN 61800-5-1 (Test
Fc of IEC 60068-2-6)
Operation 5.9 m/s
2
(0.6 g)
Transportation (Note) Class 2M3 (IEC/EN 60721-3-2)
Vibration
load
Storage Class 1M2 (IEC/EN 60721-3-2)
Pollution degree 2
Except terminal block IP20 (IEC/EN 60529) and fan finger guard
IP rating
Open type (UL 50)
Operation, storage 1000 m or less above sea level
Altitude
Transportation 10000 m or less above sea level
Note. In regular transport packaging