201612
WIRELESS REMOTE CONTROL RCN-E2,RCN-EK2
USERꞌS MANUAL
USER’S MANUAL
ENGLISH
MANUEL DE L’UTILISATEUR
ANWENDERHANDBUCH
DEUTSCH
ISTRUZIONI PER L’USO
ITALIANO
MANUAL DEL PROPIETARIO
ESPAÑOL
GEBRUIKERSHANDLEIDING
NEDERLANDS
О∆НГІЕΣ ХРНΣНΣ
MANUAL DO UTILIZADOR
PORTUGUÊS
ЕΛΛΗNIKA
РУССКИЙ
FRANÇAIS
РУКОВОДСТВО ПО ЗКСПЛУАТАЦИИ
TÜRKÇE
KULLANIM KILAVUZU
This air-conditioner complies with following directive.
Machinery 2006/42/EC
Low Voltage 2014/35/EU
EMC 2014/30/EU
Pressure Equipment 2014/68/EU
RoHS 2011/65/EU
Ecodesign 2009/125/EC
CE marking is applicable to the area of 50 Hz power supply.
Ce climatiseur est conforme aux directives suivantes.
Machines 2006/42/CE
Basse tension 2014/35/UE
CEM 2014/30/UE
Équipements sous pression 2014/68/UE
RoHS 2011/65/UE
Écoconception 2009/125/CE
La marque CE s’applique aux régions alimentées en courant de 50 Hz.
Diese Klimaanlage erfüllt die folgende Richtlinie.
Maschinen 2006/42/EC
Niederspannung 2014/35/EU
EMV 2014/30/EU
Druckgeräte 2014/68/EU
RoHS 2011/65/EU
Ökodesign 2009/125/EC
Die CE-Marke gilt für Bereiche mit einer Netzstromversorgung von 50 Hz.
Questo condizionatore d’aria è conforme alla seguente direttiva.
Macchinario 2006/42/CE
Bassa tensione 2014/35/UE
EMC 2014/30/UE
Apparecchiature a pressione 2014/68/UE
RoHS 2011/65/UE
Ecodesign 2009/125/CE
Il marchio CE è applicabile alla fascia di alimentazione 50 Hz.
Este aire acondicionado cumple con la siguiente directiva.
Máquinas 2006/42/CE
Baja tensión 2014/35/UE
EMC 2014/30/UE
Equipos a presión 2014/68/UE
RoHS 2011/65/UE
Ecodiseño 2009/125/CE
La indicación CE sólo corresponde al área de suministro eléctrico de 50 Hz.
Deze airconditioner voldoet aan de volgende richtlijn.
Machine 2006/42/EC
Laagspanning 2014/35/EU
EMC 2014/30/EU
Drukapparatuur 2014/68/EU
RoHS 2011/65/EU
Ecodesign 2009/125/EC
CE-markering is van toepassing op het gebied met een netstroom van 50 Hz.
Este ar condicionado está em conformidade com as seguintes directivas.
Máquinas 2006/42/CE
Baixa tensão 2014/35/UE
EMC 2014/30/UE
Equipamentos sob pressão 2014/68/UE
RoHS 2011/65/UE
Concessão ecológica 2009/125/CE
A marca CE aplica-se à zona de fornecimento de energia a 50 Hz.
Το συγκεκριμένο κλιματιστικό συμμορφώνεται προς καθεμιά από
τις οδηγίες που ακολουθούν.
2006/42/ΕΚ περί μηχανημάτων
2014/35/ΕΕ περί χαμηλής τάσης
2014/30/ΕΕ περί ηλεκτρομαγνητικής συμβατότητας (EMC)
2014/68/ΕΕ περί εξοπλισμού υπό πίεση
2011/65/ΕΕ RoHS
2009/125/ΕΚ περί οικολογικού σχεδιασμού
Tο σήμα CE ισχύει μόνον σε περιοχές όπου η τροφοδοσία είναι 50 Hz
ORIGINAL INSTRUCTIONS
PJZ012A128
A
Question and Answer IconNeed help?

Do you have a question about the Mitsubishi RCN-E2 and is the answer not in the manual?

Summary

Before You Use

Safety Precautions

Crucial safety guidelines and warnings to ensure proper and safe operation of the unit.

Precautions for Waste Disposal

Remote Control Specifications

Names and Functions of Remote Control Button

How to Operate

Guideline of Room Temperature Setting

Recommended temperature settings for different operation modes.

Operation Modes and Conditions

Information on changing modes and operating with existing settings.

Wireless Remote Control Handling Procedure

Battery Management and Replacement

Covers battery replacement, settings after replacement, and battery information.

Remote Control Operation and Safety

Includes switch operation cautions, basic operation, and remote control holder mounting.

How to Operate

Setting Operation Modes

Step-by-step guide to operating the air conditioner via the remote control buttons.

Setting Timers and Special Functions

Instructions for using timer, sleep, program, HI POWER, SILENT, and NIGHT SETBACK functions.

Current Time Setting Procedure

On - Timer Operation by Clock

Off - Timer Operation by Clock

Sleep Timer Operation

Program Timer Operation

Indoor Function Settings

How to Set Indoor Functions

Steps to access and set various indoor unit functions using the remote.

Setting Details

Table detailing function codes for FAN SPEED, MODE, FILTER, U/P, SILENT, HI POWER, ON TIMER, OFF TIMER, NIGHT SETBACK.

Backup Switch Operation

Check Indication

Error Indication for Different Models

Explains how error codes and LED blinks indicate malfunctions across various unit types.

Filter Sign

Filter Cleaning and Reset

How to identify and reset the filter cleaning indicator for different models.

Overview

This document is the User's Manual for the WIRELESS REMOTE CONTROL models RCN-E2 and RCN-EK2, designed for packaged air conditioners. It provides essential information for safe and proper operation, maintenance, and troubleshooting.

Function Description

The wireless remote control allows users to manage various aspects of their air conditioner's operation. Key functions include:

  • ON/OFF Control: Initiates or stops the air conditioner's operation.
  • Mode Selection: Cycles through different operating modes such as AUTO, COOL, HEAT, FAN, and DRY.
  • Temperature Adjustment: Sets the desired room temperature using up/down buttons.
  • Fan Speed Control: Adjusts the fan speed through multiple settings (1-speed, 2-speed, 3-speed, 4-speed, AUTO).
  • Airflow Direction Control:
    • Up/Down Airflow (U/D): Controls the vertical louver position.
    • Left/Right Airflow (L/R): (RCN-EK2 only) Controls the horizontal louver position.
    • 3D AUTO Mode: (RCN-EK2 only) Automatically controls both fan speed and airflow direction for efficient room conditioning.
  • Timer Operations:
    • Current Time Setting: Allows users to set the accurate current time.
    • ON-TIMER Operation: Programs the air conditioner to start at a specified time.
    • OFF-TIMER Operation: Programs the air conditioner to stop at a specified time.
    • SLEEP TIMER Operation: Stops the air conditioner after a set duration (e.g., 1 to 12 hours), promoting energy saving and comfort during sleep.
    • PROGRAM TIMER Operation: Combines ON and OFF timers to automate daily operation and stopping times.
  • Specialized Operations:
    • ECO Mode: Activates energy-saving operation in COOL, HEAT, or AUTO modes by automatically adjusting performance based on outdoor temperature and setting standard temperatures (28°C for cool, 22°C for heat).
    • HI POWER Mode: Initiates a high-power operation for 15 minutes to quickly reach a comfortable room temperature in COOL or HEAT modes, then returns to normal operation.
    • SILENT Mode: Prioritizes quiet operation by controlling the outdoor unit.
    • NIGHT SETBACK Mode: (Home leave mode) Prevents extreme room temperature fluctuations when the user is away, with configurable temperature rules for cooling (35°C/33°C) and heating (0°C/10°C) and fan speed rules.
  • Indoor Function Settings: (Available only with master wireless receiver) Allows configuration of various indoor unit functions, including:
    • Fan speed settings (Standard, Setting 1, Setting 2).
    • Room heating temperature adjustment (Disable, +1°C, +2°C, +3°C).
    • Filter sign display settings (OFF, 180 hours, 600 hours, 1000 hours, or operation stop after 1000 hours).
    • Anti-draft setting (Disable, Enable).
    • Infrared sensor settings (Motion sensor setting: Disable/Enable; Motion sensor control: Disable/Power control only/Auto OFF only/Power control and Auto OFF).
    • Cooling fan residual-period running (Disable, 0.5 hours, 2 hours, 6 hours).
    • Heating fan residual-period running (Disable, 0.5 hours, 2 hours, 6 hours).
    • Remote control signal receiver LED brightness (High, Low, OFF).
  • Check Indication: Displays error codes on the monitor or through LED blinks to indicate malfunctions, assisting in troubleshooting and communication with service personnel.
  • Filter Sign: Indicates when the air filter needs cleaning through LED blinks.

Important Technical Specifications

  • Product Dimensions: 60 (W) x 167 (H) x 24 (D) mm (excluding protruded section).
  • Weight: 0.11 kg.
  • Power Supply: DC 3.0 V (requires two AAA batteries).
  • Usage Environment Temperature: 0 to 40 °C.
  • Casing Material: ABS.
  • Compliance: The air conditioner complies with various directives, including Machinery 2006/42/EC, Low Voltage 2014/35/EU, EMC 2014/30/EU, Pressure Equipment 2014/68/EU, RoHS 2011/65/EU, and Ecodesign 2009/125/EC. CE marking applies to 50 Hz power supply areas.

Usage Features

  • Display Section: Features a liquid crystal display showing operation mode, set temperature, sleep timer time, indoor function setting number, fan speed, up/down and left/right airflow positions, current time, and indicators for ON/OFF TIMER, ECO mode, HI POWER, NIGHT SETBACK, SILENT, motion sensor, anti-draft setting, and child lock.
  • Operation Section: Includes various buttons for direct control: ON/OFF, MODE, TEMP (up/down), FAN SPEED, U/D (up/down louver), L/R (left/right louver - RCN-EK2 only), 3D AUTO (RCN-EK2 only), ON TIMER, OFF TIMER, SET, CANCEL, SLEEP, ECO, HI POWER, SILENT, NIGHT SETBACK, FILTER, FUNCTION SETTING switch, TIME SETUP switch, and ACL switch.
  • Backup Switch: Located on the indoor unit's display section, this switch allows basic ON/OFF operation of the air conditioner in case the remote control is missing or defective. It operates in AUTO mode with a set temperature of 23°C and 3-speed fan.
  • Remote Control Holder: The remote control can be mounted on a wall or pillar using the provided holder for convenient access.
  • Child Lock: Can be enabled by pressing and holding the SET button to prevent unintended operation.
  • Centralized Control Integration: Notes that some functions may be overridden or linked when the system is connected to a centralized device or wired remote control.

Maintenance Features

  • Battery Replacement:
    • Indicated by the air conditioner not displaying reception, a fading display, or no display.
    • Requires two new AAA alkaline batteries.
    • It's recommended to replace both batteries simultaneously and avoid mixing old and new or different types of batteries. Rechargeable batteries are not recommended.
    • After battery replacement, remote control settings, indoor function settings, and time display reset to default and must be reconfigured.
  • Cleaning the Remote Control:
    • Avoid using benzene, paint thinner, or wipes as they can cause discoloration or damage.
    • Wipe with a cloth squeezed tightly after wetting with diluted neutral detergent, then finish with a dry cloth.
  • Filter Cleaning Indication: The FILTER SIGN LED blinks to remind users to clean the air filter. After cleaning, press the FILTER button on the remote control to reset the sign. The default setting for this reminder is 180 hours, but it can be changed in the indoor function settings.
  • Error Indication: The CHECK MODE INDICATOR and various LEDs (RUN, TIMER/CHECK, CHECK1, CHECK2, FILTER SIGN) on the indoor unit's display section provide visual cues (blinking patterns or codes) for malfunctions, aiding in diagnosis and repair by service technicians.
  • General Care:
    • Keep the remote control away from direct sunlight and extreme temperatures (above 40°C or below 0°C) to prevent deformation or discoloration.
    • Do not disassemble the remote control.
    • Avoid washing the remote control with water or liquid.
    • Do not touch electrical parts or operate buttons with wet hands.
    • Do not tap buttons or screens with pointed objects.
    • Remove batteries if the remote control will not be used for a long time.
  • Waste Disposal: The product is marked with the WEEE symbol, indicating it should not be mixed with general household waste. It should be treated at an authorized facility for re-use, recycling, and recovery. Users should contact their installer or local authority for disposal information.

Mitsubishi RCN-E2 Specifications

General IconGeneral
BrandMitsubishi
ModelRCN-E2
CategoryRemote Control
LanguageEnglish