19
2 Basic Measuring Methods
No. 99MAF600B
1
Press [MODE].
» Characters and icons will be displayed in the bottom row
of the LCD.
2
Press [Outside diameter measurement] and select the icon for [Probe settings].
M1 M2
3
Press [ENTER].
» An icon will be displayed in the upper left of the LCD
([↓]willblink).
4
Measure the top surface of the ball diameter calibration block.
1 Install the ball diameter calibration block.
2 Loosen the clamp knob.
3 Loosen the clamp screw.
4 Turn the probe unit up/down wheel, and slowly bring the stylus into contact with the top surface of the ball
diameter calibration block until there is a "beep" sound.
2
3
4
4
» An icon will be displayed
in the upper left of the LCD
([]willblink).