EasyManua.ls Logo

MKS TFT24 - 6.3 Automatic Leveling and Manual Leveling; 6.4 Filament Change Function

MKS TFT24
44 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6.3 Automatic Leveling and Manual leveling
1 . Equipped with a leveling device can be selected in the configuration file automatic leveling (the position
of the arrow is configured to 1), in the Touch screen settings interface can be adjusted leveling.Attention:For
motherboards using the smoothie firmware, select the command to send as G32, as shown below:
2 . Manual leveling can be used on the general model structure (MB, I3, etc.), set in the configuration file
needs to be in the hot bed leveling the three point leveling, four point leveling or five point leveling, the
following figure:
6.4 Filament Change Function
Filament Change Function, so that you more convenient to replace the supplies, you can also pause in the
printing point after the use of the feed function. The extrusion head rotation speed and minimum
temperature can be configured in the configuration file, as shown in the following figure: