23
when assembling and dissembling, as this could cause a deterioration of the mechanical
parts.
Maintenance of the Portable Valve Actuators should be carried out by people who have
been trained by modec.
Our “After Sales Service” department are ready to help in this respect.
Systematically disconnect the actuator from the power feed (battery pack or mains)
before carrying out any procedure that involves replacing, adjusting, servicing or
dissembling the actuator or any of its parts.
Every time maintenance is carried out, test the actuator afterwards to check it is
working correctly.
Only use approved replacement parts and follow the manufacturer’s advice with regard to
lubrication and waterproofing.
12. Problem solving
Electric Portable Valve Actuator MC89
Symptoms
Probable causes
Checks & solutions
Repaired by
The actuator doesn’t
start
Direction switch button is not
activated
Press switch correctly to the left or the right
User
Battery not properly in place
Insert the battery correctly
User
The actuator beeps
once and stops
Battery pack is empty / not
charged
Charge / change the battery pack
User
Actuator overloaded (torque is
too high)
Reduce load
User
Actuator has overheated
Let it cool down a few minutes
User
The actuator beeps
once and the led
flashes continuously
Torque reaction safety has
triggered
Release the On/Off switch, fix a torque
reaction system and start again
User
The actuator beeps
continuously
The motor is faulty
Contact a modec Service center
modec Distributor
Revolution counter (optional)
Symptom
Screen
status
Probable causes
Checks
Solutions
Repaired by
The counter
doesn’t give a
reading
Off
Timer elapsed /
automatic stop
Activate the “ON”
button
User
Flat battery
Check the state of
the battery
Change the battery
User
Screen is out of order
Check with a
registered modec
distributor
Change the screen
modec Distributor
The counter is on
but doesn’t count
On and
not
moving
Poor connection
between the captor
and the card
Check the sensor
connection
Reconnect the
sensor
User
modec Distributor
Captor and/or the card
is out of order
Check with a
registered modec
distributor
Change the
electronic card
modec Distributor