RESEARCH AND DEVELOPMENT
3
You can reach this status by pressing the START/STOP key for long while in the OFF status. The
display shows the chamber probe code “SCA”. By pressing the UP and DOWN keys, you pass to
the heating element probe “SrE”. Pressing START/STOP displays the value read by the indicated
probe; if the probe is in error, “Err” will appear. By pressing START/STOP you exit the viewing of
the value. You may return to the OFF status by pressing the START/STOP key or after a 5 second
timeout.
FIRMWARE REV DISPLAY STATUS
You can reach this status by pressing the ON/OFF key for long while in the OFF status. The
display alternately shows the firmware version and revision code. You may return to the OFF
status by pressing the ON/OFF key or after a 5 second timeout.
4 KEYS PC BOARDS DIAGNOSTICS
CAVITY PROBE MALFUNCTION
The display shows the code Er1.
The cycle in progress is blocked and the buzzer switches on (it can be silenced by pressing a key).
It can be caused by an incorrect connection of the probe or by a failure of the same.
HEATING ELEMENT PROBE MALFUNCTION
The Display shows the code Er2.
The cycle in progress is blocked and the buzzer switches on (it can be silenced by pressing a key).
It can be caused by an incorrect connection of the probe or by a failure of the same.