Message byte
69
04/99 AWB 27-1184 GB
The status information indicates, for example,
whether:
The device ID is incorrect
The device has been disconnected from the
Suconet bus or does not respond
There is a short-circuit at the digital output of the
station, etc.
The status information and its meaning are described
in the manuals for the respective Suconet stations
and local expansion modules.
Message byte The message byte contains information about the
status of the PLC, image data relating to the network
stations, the PLC’s startup behaviour, etc. You only
have read access to this information.
For further information on message byte, refer to the
“PLC_Message” function block description in the
manual “Language elements for the PS4-150/
-200/-300 and PS416” (AWB2700-1306GB).