EasyManua.ls Logo

MOKO MK107 - Configure APP and Device Connect to AWS Iot

MOKO MK107
18 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
www.mokosmart.com
4
Type
Description
Broker setting
The IP address or domain name of your server.
Server port number.
MQTT client id, each device connected to the server
should have a unique client id.
Topics
The gateway uses it to subscribe messages from the APP.
You can use the default topic directly or modify it.
If the topic of “Settings for APP” page has been set, it
should be set the same as the APP published topic.
The gateway uses it to publish messages to the APP. You
can use the default topic directly or modify it.
If the topic of “Settings for APP” page has been set, it
should be set the same as the APP subscribed topic.
General
Default: Enable, range: Enable/Disable
Quality of service. Default: 1, range: 0-2
Default : 60, range: 10-120
User Credentials
If access to your server doesn’t require a username and
password, it can be blank.
SSL/TSL
Enable means SSL mode
Disable means TCP mode
It supports three type of certificates:
CA signed server certification;
CA certificate file;
Self signed certificates
Device Id
Each added device should have a unique device id.
Time setting
NTP server IP or domain name, it can be blank, then
device will use the default NTP server.
Default: UTC+0, range: UTC-12 - UTC+12
2.2.2 Configure APP and Device connect to AWS iot
When configuring the gateway to connect to AWS iot, please enable the SSL/TSL option, then
select the certificate files locally from the mobile phone.