Fan Calibration: Menu for setting the combustion air Fan speed. There
are 10 levels, 5 to increase and 5 to decrease, the 0 level is the
manufacturers default value.
Once Fan Calibration has been selected:
Enter edit mode (flashing cursor) by pressing SET.
Modify the selected value with and save the setting by
pressing SET.
Press ESC to exit.
Note: the number shown when editing a parameter refers only to a
percentage value which acts on default parameters (exclusively in
Run mode and Modulation). Each of these values must be changed
in case of a poor combustion due to the use of a different (from the
first ignition test) quality of pellets.
See COMBUSTION for further details.
Monitor
Menu for monitoring parameters and functions of the system.
To navigate in the menu use the
buttons. Press ESC to
exit.
Auger Calibration
Fan Calibration
Fan Calibration
Max: 5
Set: 0
Min: -5
Load
The menu allows the manual filling of the auger. The stove must be
OFF for this function to be activated. If the Auger is manually
activated, then the Exhaust Fan is also activated, this is necessary so
that the pressure switch can close the contact and the auger can turn.
To select the item in the menu use the buttons. To
confirm press SET. To exit press ESC.
Clean
Menu that activates or deactivates the automatic burner
cleaning system (PLUS CLEAN models only), This
process takes place during the ignition phase. It is
recommended to keep it activated.
To select the item in the menu use the buttons. To
confirm press SET. To exit press ESC.
Language
Menu that allows to set a desired language.
To select the item in the menu use the buttons. To
confirm press SET. To exit press ESC.
Settings
To select the item in the menu use the buttons. To
confirm press SET. To exit press ESC.
Thermostat Management: The Menu allows to set the radio room
thermostat function.
Radio Standby: Menu for deactivating the display radio.
Load
Off
On
Monitor
T. Fumes
T. Boiler
Pressure
Monitor
Clean
Product Code 32
FSYSD0100001
Monitor
Air Flux
Fan Speed
Auger
Calibration
Load
Clean
Language
Settings
Monitor
Monitor
FSYSC0200001
Calibration
Monitor
Clean
Language
Settings
Load
Clean
Off
On
Calibration
Monitor
Load
Language
Settings
Clean
Radio Standby
Radio Test
Change Code
Set Contrast
Key Tone
Thermostat Manage
Thermostat
Managem
Enabled
Disabled
Calibration
Monitor
Load
Clean
Language
Settings

Related product manuals