Do you have a question about the Moretti Design AQUA and is the answer not in the manual?
Brand | Moretti Design |
---|---|
Model | AQUA |
Category | Stove |
Language | English |
Provides essential safety guidelines for operating the hydro stove, emphasizing compliance with regulations.
Details the identification plate on the hydro stove, listing crucial technical specifications and certifications.
Instructions for receiving, unpacking, and preparing the hydro stove for installation, including handling precautions.
Guidance on the physical assembly and connection of the hydro stove, stressing the need for qualified personnel.
Explains the importance of proper air circulation for combustion and methods to ensure adequate ventilation.
Details requirements for installing a flue system to safely expel combustion fumes, adhering to regulations.
Instructions for correctly installing an optional remote thermostat to control the hydro stove's operation.
Procedure for filling the heating system with water after installation, including bleeding air pockets.
Specifies minimum clearances required between the stove and flammable materials for safe operation.
Guidance on correctly positioning the display radio antenna for optimal signal reception and stove control.
Instructions on how to properly load wooden pellets into the fuel tank for operation.
Details the steps required to initiate the first ignition sequence of the hydro stove.
Explains the automatic combustion control system that optimizes efficiency by adjusting fuel and air dosage.
Describes how to calibrate the combustion system for optimal performance, with or without FCS.
Overview of the wireless display radio, its features, and its role in controlling the hydro stove.
Explains the function of each button on the display radio remote control for various operations.
Details the different operating statuses displayed on the remote control, indicating the stove's current mode.
Settings for controlling the radio and boiler thermostats to manage room and water temperatures.
Menu option for selecting the type of fuel (pellets) used by the hydro stove.
Function to enable or disable the remote keyboard connection to the hydro stove.
Setting for selecting the operating mode between Summer and Winter configurations.
Menu for programming the on/off switching time frames for automated operation.
Allows setting the current time and date for accurate operation and programming.
Detailed programming of time frames for daily, weekly, and weekend on/off switching cycles.
Setting up timed on/off cycles for each day of the week, with multiple time frames.
Programming timed on/off cycles that repeat throughout the week.
Setting timed on/off cycles specifically for weekend periods.
Adjusting automatic combustion correction range on models equipped with FCS for optimal burning.
Manually regulating combustion parameters like auger and fan settings on models without FCS.
Manual filling of the auger with pellets, requiring the stove to be turned off.
Activating or deactivating the automatic burner cleaning system for PLUS CLEAN models.
Viewing system parameters and functions, such as temperature, pressure, and fan speed.
Table detailing the meaning of different operating status indicators displayed on the control panel.
Explanation of the functions associated with each button on the emergency control panel.
Accessing and viewing various operational parameters and settings through the user menu.
Adjusting automatic combustion correction range on models with FCS using specific levels.
Menu for setting on/off switching time frames, with options for daily, weekly, and weekend programming.
Selecting and programming specific time frames for automated stove operation.
Programming daily on/off switching time frames with multiple phases.
Setting weekly on/off time frames that repeat throughout the week.
Programming on/off time frames specifically for weekend periods.
Error code for safety thermostat intervention due to high water or pellet tank temperature.
Error code indicating switch-off due to chimney flue occlusion or wind in the flue.
Error code for turn-off due to low fume temperature or blocked auger.
Error code for switch-off due to high water temperature or pump issues.
Error code for turn-off due to high fume temperature or dirty stove.
Error code for turn-off due to encoder error or no signal to encoder.
Error code for turn-off due to encoder error or non-setting encoder.
Error code for switch-off due to low pressure in the heating system.
Error code for switch-off due to high pressure in the heating system.
Error code indicating a clock error or problem with the control unit.
Error code for ignition failure, possibly due to empty pellet tank or ignition resistance.
Error code for turn-off due to power failure or blackout.
Error code for switch-off due to anomaly in the automatic burner cleaning system.
Error code for turn-off due to flowmeter error, indicating connection or sensor issues.
Error code for door micro switch intervention, indicating open doors.
Indicates no transmission between the display radio and the stove, requiring code change or proximity check.
Procedure to reset the manual safety thermostat by accessing and pressing the internal button.
Instructions for cleaning the burner before each ignition to ensure optimal combustion and prevent issues.
Guidance on how to safely access and empty the ash drawer for regular maintenance.
Procedure for monthly cleaning of the pellet tank to remove accumulated dust.
Recommendations for cleaning the stove's painted metal surfaces without damaging them.
Essential precautions and guidelines for fire safety, including clearances and building regulations.
Information on how to obtain and validate the product warranty within the specified timeframe.
Details on what components are covered by the warranty and common exclusions.
Standard setting for integrating the hydro stove with domestic hot water and heating systems.
Details the second hydraulic system configuration for integrating the hydro stove with heating and water systems.
Describes the third hydraulic system configuration, including connections and operational parameters.
Outlines the fourth hydraulic system configuration, detailing probe and pump connections and system logic.
Specifies the fifth hydraulic system configuration, focusing on puffer integration and temperature differentials.
Note stating that configurations 5 and 6 are not compatible with Moretti Fire hydro stoves.