EasyManua.ls Logo

Moretti Design AQUA User Manual

Moretti Design AQUA
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
1
USER MANUAL
HYDRO STOVE
AQUA
Question and Answer IconNeed help?

Do you have a question about the Moretti Design AQUA and is the answer not in the manual?

Moretti Design AQUA Specifications

General IconGeneral
BrandMoretti Design
ModelAQUA
CategoryStove
LanguageEnglish

Summary

Introduction and Description

General Safety Warnings

Provides essential safety guidelines for operating the hydro stove, emphasizing compliance with regulations.

Identification

Details the identification plate on the hydro stove, listing crucial technical specifications and certifications.

Installation Procedures

Supply Conditions and Unpacking

Instructions for receiving, unpacking, and preparing the hydro stove for installation, including handling precautions.

Assembling the Stove

Guidance on the physical assembly and connection of the hydro stove, stressing the need for qualified personnel.

Combustion Air Requirements

Explains the importance of proper air circulation for combustion and methods to ensure adequate ventilation.

Fume Exhaust System

Details requirements for installing a flue system to safely expel combustion fumes, adhering to regulations.

Installing Remote Thermostat

Instructions for correctly installing an optional remote thermostat to control the hydro stove's operation.

Filling the Heating System

Procedure for filling the heating system with water after installation, including bleeding air pockets.

Safety Devices and Distances

Minimum Safety Distances

Specifies minimum clearances required between the stove and flammable materials for safe operation.

First Ignition and Combustion

Positioning the Antenna

Guidance on correctly positioning the display radio antenna for optimal signal reception and stove control.

Pellet Loading Procedure

Instructions on how to properly load wooden pellets into the fuel tank for operation.

Ignition Mode

Details the steps required to initiate the first ignition sequence of the hydro stove.

FCS (Fire Control System)

Explains the automatic combustion control system that optimizes efficiency by adjusting fuel and air dosage.

Combustion Calibration

Describes how to calibrate the combustion system for optimal performance, with or without FCS.

Display Radio Operation

Display Radio Introduction

Overview of the wireless display radio, its features, and its role in controlling the hydro stove.

Button Description

Explains the function of each button on the display radio remote control for various operations.

Operating Status Display

Details the different operating statuses displayed on the remote control, indicating the stove's current mode.

Menu System Navigation

Thermostat Settings

Settings for controlling the radio and boiler thermostats to manage room and water temperatures.

Fuel Selection

Menu option for selecting the type of fuel (pellets) used by the hydro stove.

Remote Keyboard Settings

Function to enable or disable the remote keyboard connection to the hydro stove.

Summer Winter Mode

Setting for selecting the operating mode between Summer and Winter configurations.

Chrono Timer Settings

Menu for programming the on/off switching time frames for automated operation.

Time and Date Adjustment

Allows setting the current time and date for accurate operation and programming.

Chrono Program Configuration

Detailed programming of time frames for daily, weekly, and weekend on/off switching cycles.

Daily Chrono Program

Setting up timed on/off cycles for each day of the week, with multiple time frames.

Weekly Chrono Program

Programming timed on/off cycles that repeat throughout the week.

Weekend Chrono Program

Setting timed on/off cycles specifically for weekend periods.

Calibration Models with FCS

Adjusting automatic combustion correction range on models equipped with FCS for optimal burning.

Calibration Models without FCS

Manually regulating combustion parameters like auger and fan settings on models without FCS.

Load Function

Manual filling of the auger with pellets, requiring the stove to be turned off.

Clean Function

Activating or deactivating the automatic burner cleaning system for PLUS CLEAN models.

Monitor System Parameters

Viewing system parameters and functions, such as temperature, pressure, and fan speed.

Emergency Control Panel Features

Operating Status Indicators

Table detailing the meaning of different operating status indicators displayed on the control panel.

Emergency Panel Button Functions

Explanation of the functions associated with each button on the emergency control panel.

User Menu 1 - Monitor

Accessing and viewing various operational parameters and settings through the user menu.

User Menu 2 Options

MCS Menu (models with FCS)

Adjusting automatic combustion correction range on models with FCS using specific levels.

Chrono Menu (Cron)

Menu for setting on/off switching time frames, with options for daily, weekly, and weekend programming.

Chrono Program (PrOG)

Selecting and programming specific time frames for automated stove operation.

Daily Chrono Program Setup

Programming daily on/off switching time frames with multiple phases.

Weekly Chrono Program Setup

Setting weekly on/off time frames that repeat throughout the week.

Weekend Chrono Program Setup

Programming on/off time frames specifically for weekend periods.

Error and Message Codes

Er01: Safety Thermostat Intervention

Error code for safety thermostat intervention due to high water or pellet tank temperature.

Er02: Chimney Flue Occlusion

Error code indicating switch-off due to chimney flue occlusion or wind in the flue.

Er03: Low Fume Temperature / Blocked Auger

Error code for turn-off due to low fume temperature or blocked auger.

Er04: High Water Temperature

Error code for switch-off due to high water temperature or pump issues.

Er05: High Fume Temperature / Dirty Stove

Error code for turn-off due to high fume temperature or dirty stove.

Er07: Encoder Error / No Signal

Error code for turn-off due to encoder error or no signal to encoder.

Er08: Encoder Error / Non-Setting Encoder

Error code for turn-off due to encoder error or non-setting encoder.

Er09: Low System Pressure

Error code for switch-off due to low pressure in the heating system.

Er10: High System Pressure

Error code for switch-off due to high pressure in the heating system.

Er11: Clock Error / Control Unit Issue

Error code indicating a clock error or problem with the control unit.

Er12: Ignition Failure

Error code for ignition failure, possibly due to empty pellet tank or ignition resistance.

Er15: Power Failure / Blackout

Error code for turn-off due to power failure or blackout.

Er25: Burner Cleaning System Anomaly

Error code for switch-off due to anomaly in the automatic burner cleaning system.

Er39/Er41/Er42: Flowmeter Error

Error code for turn-off due to flowmeter error, indicating connection or sensor issues.

Er44: Door Open Warning

Error code for door micro switch intervention, indicating open doors.

No Signal Transmission

Indicates no transmission between the display radio and the stove, requiring code change or proximity check.

Control Unit Overview

Safety Thermostat Reset and Maintenance

How to Reset Safety Thermostat (Er01)

Procedure to reset the manual safety thermostat by accessing and pressing the internal button.

Burner Cleaning

Instructions for cleaning the burner before each ignition to ensure optimal combustion and prevent issues.

Emptying the Ash Drawer

Guidance on how to safely access and empty the ash drawer for regular maintenance.

Pellet Tank Cleaning

Procedure for monthly cleaning of the pellet tank to remove accumulated dust.

Surface Cleaning

Recommendations for cleaning the stove's painted metal surfaces without damaging them.

Fire Protection and Warranty

Fire Protection Guidelines

Essential precautions and guidelines for fire safety, including clearances and building regulations.

Warranty Certification Process

Information on how to obtain and validate the product warranty within the specified timeframe.

Warranty Conditions and Exclusions

Details on what components are covered by the warranty and common exclusions.

Plumbing Configuration Options

Configuration 0: Standard Setting

Standard setting for integrating the hydro stove with domestic hot water and heating systems.

Configuration 1

Details the second hydraulic system configuration for integrating the hydro stove with heating and water systems.

Configuration 2

Describes the third hydraulic system configuration, including connections and operational parameters.

Configuration 3

Outlines the fourth hydraulic system configuration, detailing probe and pump connections and system logic.

Configuration 4

Specifies the fifth hydraulic system configuration, focusing on puffer integration and temperature differentials.

Configurations 5 & 6 Incompatibility

Note stating that configurations 5 and 6 are not compatible with Moretti Fire hydro stoves.

Related product manuals