2423
MAINTENANCE
TROUBLESHOOTING
Fuse replacement
WARNING!
For continued protection against risk of re or electric shock, replace only with a fuse of the same
type and ratings (12 V, 8 A).
Follow the instructions to replace the fuse inside the cigarette lighter plug of your connector cable (J):
Unscrew the upper cover of the cigarette lighter plug.
Remove the faulty fuse.
Insert a new fuse and screw the cover of the plug back on.
NEW FUSE
FAULTY FUSE
The inverter is equipped with protective shutdown features and an acoustic signal.
The details are listed in the following table:
ALARM POSSIBLE CAUSE SOLUTION
ERROR
SIGNAL
Low battery
alarm and
low-voltage
shutdown
As the battery discharges, its
voltage decreases. Voltage drops
to: 10.511.0 V = alarm.
Shut down sensitive loads such as
computers and then recharge the
battery.
Audible
alarm
Voltage drops to:
10.010.5 V = shutdown.
This protects the battery from
being over-discharged.
Recharge the battery.
Red
indicator
light (G)
turns on
High-
voltage
shutdown
A defective battery charging
system can cause the battery
voltage to rise to high levels
(15.016.3 V).
Although the inverter has a
protection against high voltage,
it might still be damaged if the
input voltage were to exceed 16 V.
Disconnect the connected devices.
Verify that the charging system is
properly regulated and the battery is
12V nominal.
Red
indicator
light (G)
turns on
Overload
shutdown
If you connect a device that is
rated too high or a load that draws
excessive surge power, the power
inverter shuts down.
Use a product with a power rating
within the inverter’s continuous
power rating (
Operation).
Red
indicator
light (G)
turns on
Overheat
shutdown
The power inverter shuts down
automatically if it exceeds its safe
operating temperature.
• Switch the inverter o and
disconnect it from the cigarette
lighter socket.
• Disconnect all connected devices
and allow the inverter to cool for
at least 15 minutes.
• Use a brush to clear any blocked
ventilation holes.
• Move the inverter to a cooler
place. Reduce the load if
continuous operation is required.
Red
indicator
light (G)
turns on