Table 10: Charging Indications for IMPRES 2 or IMPRES Battery (Calibration Required, but Not
Enabled)
Status Pocket Display LED Indicator
Charger Powers On
IMPRES 2
CHARGER
Green for approximately 1 sec-
ond
Battery Detected
IMPRES 2
BATTERY
OR
IMPRES
BATTERY
Battery requires Calibration,
but Calibration is disabled in
charger.
Alternating amber and green
for four seconds.
Requesting IMPRES Battery
Calibration
Calibration is disabled in
charger.
Battery is charging.
WARNING:
ENABLE
BATTERY CALIBRATION?
NOTE: Press OK to enable
calibration and ignore for
normal charging. Message is
removed after 1 minutes.
Steady red
Rapid Charging
Request for Calibration
timed out.
RAPID CHARGE
xxxx0mAh yyy%Ptl
Steady red
Charged to 90% or more
TRICKLE CHARGE
xxxx0mAh yyy%Ptl
Flashing green
Charged to 95% or more
CHARGE COMPLETE
xxxx0mAh yyy%Ptl
Alternating amber and green
Fault WARNING:
NOT CHRAGEABLE
REMOVE & REINSERT
Flashing red
Standby
Battery is waiting to rapid
charge.
Battery is too hot, too
cold, or low voltage.
Charger is too hot.
WARNING:
HOT BATTERY
WAITING TO CHRGE
OR
COLD BATTERY
WAITING TO CHRGE
OR
VERY LOW BATTERY
WAITING TO CHRGE
OR
HOT CHARGER
WAITING TO CHRGE
Flashing amber
MN002407A01-AK
Chapter 5: Charging Indication
29