Test Equipment 3-3
2.0 Test Equipment
Table 3-2 lists test equipment required to service the radio and other two-way radios.
Table 3-2 Test Equipment
Motorola Part No. Description Characteristics Application
R2600_NT Comms System
Analyzer
(non MPT)
This monitor will
substitute for items with
an asterisk *
Frequency/deviation meter
and signal generator for
wide-range troubleshooting
and alignment
R2680_NT
to be ordered with
RLN1022_ (H/W)
RLN1023_ (S/W)
Comms System
Analyzer (MPT1327)
This monitor will
substitute for items with
an asterisk *
Frequency/deviation meter
and signal generator for
wide-range troubleshooting
and alignment
*R1072_ Digital Multimeter AC/DC voltage and current
measurements
*R1377_ AC Voltmeter 100 µV to 300 V,
5Hz-1MHz, 10 Megohm
input impedance
Audio voltage
measurements
R1611A Dual Channel 100MHz Two-channel, 100 MHz
band- Waveform Measure-
ments. Oscilloscope (Agil-
lent width 200 M sample
rate / sec. and 2Mb mem-
ory / channel.
WADN4133_ Delay
Oscilloscope
2 Channel 40 MHz
bandwidth,
5 mV/cm - 20 V/cm
Waveform measurements
R1440_
0180305F17
0180305F22
0180305F30
0180305F31
0180305F39
RLN4610_
*T1013_
Wattmeter,
Plug-in Element
Plug-in Element
Plug-in Element
Plug-in Element
Plug-in Element
Carry case
RF Dummy Load
Thruline 50-Ohm, ±5%
accuracy
10W, 25 - 60MHz
10W, 50 - 125 MHz
10W, 100 - 250 MHz
25W, 100 - 250MHz
10W, 200 - 500 MHz
Wattmeter and
5 elements
Transmitter power output
measurements
*R1013B SINAD Meter w/o RMS Audio Voltmeter.
Receiver Sensitivity Mea-
surements.
or *R1370A SINAD Meter
w/ RMS w/ RMS Audio
Voltmeter. Receiver Sensi-
tivity Measurements.
S1348_ 220V Power Supply 0-20V, 5A Programmable