8-14 Maintenance: UHF Band 1 Troubleshooting Charts
8.10.7 Troubleshooting Flow Chart for Transmitter
START
No Power
Is There B+
Bias for Ant
switch
Check Q111
Is Current
OK?
Is Control Voltage
High or Low
Check PCIC
1. Check Pin Diodes
2. Check Harmonic Filter
Inspect/Repair Tx
Output Network
Is Power
OK?
Done
Check Drive to
Module
Is Drive
OK?
Troubleshoot
VCO
Inspect PA Network/
Check Power Out of
U101 at Cap C160
Is Power
OK?
Replace U101
Is Power
OK?
Replace Q101
Done
Done
No
Yes
Yes
No
No
Yes
Low
High
No
Yes
Yes
No
Yes
No

Table of Contents

Other manuals for Motorola HT Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Motorola HT Series and is the answer not in the manual?

Motorola HT Series Specifications

General IconGeneral
Battery TypeLi-Ion
WaterproofIP54
Operating Temperature-30°C to +60°C
Frequency RangeVHF: 136-174 MHz
Number of Channels16