Maintenance: Low Band Troubleshooting Charts 8-37
8.13.3 Troubleshooting Flow Chart for Receiver (Sheet 2 of 2)
IF Signal at
L301?
No
RF Signal at
T501?
RF Signal
at collector
Q509?
No
RF Signal at
C504?
No
RF Signal at
C147?
No or
Check transmit harmonic filter, antenna
switch and J101
Check filter between C147 &
C504
Inject RF into J101
No
Yes
Check RF amp (Q509)
Stage
Check filter between Q509&
T301
Yes
Check T501, T502, D501,
R507, R508, R509,C516,L508
Yes
1st LO O/P
310OK?
Locked?
Yes
Check FGU
Yes
Trace IF signal from
L301 to U301. Check
for bad XTAL filter
No
Yes
U301 drain
OK?
IF signal
present?
Before replacing U303,
check U303 voltages;
trace IF signal path
Yes
Biasing on U301
OK?
Troubleshoot biasing,
AGC circuits and U301
No
No
Yes
A
B
weak RF